{"title":"Home page","description":null,"products":[{"product_id":"bosch-ids-premium-inverter-heat-pump","title":"Bosch IDS Premium Inverter Heat Pump","description":"\u003cp\u003e\u003cstrong\u003eA fully modulating, whisper-quiet central heat pump designed for whole-home comfort.\u003c\/strong\u003e The Bosch IDS Premium 2.0 pairs an inverter-driven variable-capacity compressor with ducted air distribution. Instead of cycling abruptly on and off like conventional single-stage systems, it modulates in fine 1% increments between 25% and 110% capacity to precisely match your home's heating and cooling demand, providing steady indoor temperatures, reduced energy consumption, and whisper-quiet sound levels.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully modulating inverter compressor\u003c\/strong\u003e — adjusts speed automatically between 25% and 110% in 1% steps to eliminate room temperature swings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh seasonal efficiency\u003c\/strong\u003e — rated up to 20.5 SEER and 10.5 HSPF when paired with an approved Bosch BVA air handler or cased coil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhisper-quiet outdoor sound\u003c\/strong\u003e — silent blade fan technology and sound-dampening compressor blankets keep sound levels as low as 56 dB(A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide operating temperature range\u003c\/strong\u003e — delivers reliable cooling up to 52 °C (125 °F) and heating down to −15 °C (5 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal 24V thermostat compatibility\u003c\/strong\u003e — works with standard two-stage heat pump thermostats (such as Ecobee or Google Nest) without requiring proprietary communicating wall controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact cube footprint\u003c\/strong\u003e — top-discharge design with a small 740 × 740 mm footprint easily fits standard equipment pads and side yards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChoosing your capacity\u003c\/h2\u003e\n\u003cp\u003eBosch IDS inverter systems do not require separate half-ton outdoor units (such as 2.5 or 3.5 ton). Because the inverter compressor continuously modulates to match the load, the 3-Ton unit (BOVA-36) is field-switchable between 2.0 and 3.0 Ton, while the 5-Ton unit (BOVA-60) is field-switchable between 4.0 and 5.0 Ton via onboard DIP switches, seamlessly adapting to your home's ductwork and calculated heating\/cooling load.\u003c\/p\u003e\n\u003ch2\u003eSystem pairings\u003c\/h2\u003e\n\u003cp\u003eBoth outdoor condensing units pair with a matching Bosch BVA air handler for all-electric setups, or with a Bosch BMAC cased evaporator coil over an existing gas furnace for a dual-fuel hybrid system.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel number\u003c\/th\u003e\n\u003ctd\u003eBOVA-36HDN1-M20G (3.0 Ton) \/ BOVA-60HDN1-M20G (5.0 Ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eBOVA-36HDN1-M20G, BOVA-60HDN1-M20G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBosch Home Comfort\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eInverter Ducted Split (IDS) Premium 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eCentral ducted split-system heat pump condenser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eResidential ducted heating and cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompressor type\u003c\/th\u003e\n\u003ctd\u003eInverter rotary, fully modulating (25–110%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003ePerformance\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e3.0 Ton (BOVA-36HDN1-M20G)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e5.0 Ton (BOVA-60HDN1-M20G)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal capacity\u003c\/th\u003e\n\u003ctd\u003e3.0 Ton (covers 2.0–3.0 Ton)\u003c\/td\u003e\n\u003ctd\u003e5.0 Ton (covers 4.0–5.0 Ton)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling capacity range\u003c\/th\u003e\n\u003ctd\u003e12,000–36,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e18,000–60,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeating capacity range\u003c\/th\u003e\n\u003ctd\u003e12,000–36,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e18,000–60,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEfficiency rating (SEER)\u003c\/th\u003e\n\u003ctd\u003eUp to 20.5 SEER\u003c\/td\u003e\n\u003ctd\u003eUp to 20.0 SEER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeating seasonal factor (HSPF)\u003c\/th\u003e\n\u003ctd\u003eUp to 10.5 HSPF\u003c\/td\u003e\n\u003ctd\u003eUp to 10.5 HSPF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutdoor sound level\u003c\/th\u003e\n\u003ctd\u003e56–59 dB(A)\u003c\/td\u003e\n\u003ctd\u003e59–62 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBOVA-36HDN1-M20G\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBOVA-60HDN1-M20G\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage \/ frequency \/ phase\u003c\/th\u003e\n\u003ctd\u003e208\/230 V, 60 Hz, 1-Phase\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, 60 Hz, 1-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum circuit ampacity (MCA)\u003c\/th\u003e\n\u003ctd\u003e24.3 A\u003c\/td\u003e\n\u003ctd\u003e33.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum overcurrent protection (MOP)\u003c\/th\u003e\n\u003ctd\u003e35 A breaker\u003c\/td\u003e\n\u003ctd\u003e50 A breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl voltage\u003c\/th\u003e\n\u003ctd\u003e24 V AC (standard thermostat wiring)\u003c\/td\u003e\n\u003ctd\u003e24 V AC (standard thermostat wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRefrigerant and line set\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBOVA-36HDN1-M20G\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBOVA-60HDN1-M20G\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRefrigerant type\u003c\/th\u003e\n\u003ctd\u003eR-410A (pre-charged for 4.6 m \/ 15 ft)\u003c\/td\u003e\n\u003ctd\u003eR-410A (pre-charged for 4.6 m \/ 15 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLiquid line connection\u003c\/th\u003e\n\u003ctd\u003e9.5 mm (3\/8 in) sweat\u003c\/td\u003e\n\u003ctd\u003e9.5 mm (3\/8 in) sweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuction line connection\u003c\/th\u003e\n\u003ctd\u003e19.05 mm (3\/4 in) sweat\u003c\/td\u003e\n\u003ctd\u003e22.2 mm (7\/8 in) sweat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum line set length\u003c\/th\u003e\n\u003ctd\u003e30.5 m (100 ft)\u003c\/td\u003e\n\u003ctd\u003e30.5 m (100 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum vertical lift\u003c\/th\u003e\n\u003ctd\u003e15.2 m (50 ft)\u003c\/td\u003e\n\u003ctd\u003e15.2 m (50 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDimensions and weight\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBOVA-36HDN1-M20G\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBOVA-60HDN1-M20G\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W × D × H)\u003c\/th\u003e\n\u003ctd\u003e740 × 740 × 633 mm (29.13 × 29.13 × 24.92 in)\u003c\/td\u003e\n\u003ctd\u003e740 × 740 × 843 mm (29.13 × 29.13 × 33.19 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNet unit weight\u003c\/th\u003e\n\u003ctd\u003e70.3 kg (155 lb)\u003c\/td\u003e\n\u003ctd\u003e94.3 kg (208 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGross shipping weight\u003c\/th\u003e\n\u003ctd\u003e79.8 kg (176 lb)\u003c\/td\u003e\n\u003ctd\u003e104.8 kg (231 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eListings\u003c\/th\u003e\n\u003ctd\u003eAHRI Certified, UL 1995 listed, ENERGY STAR® certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThis outdoor heat pump condenser requires a matching indoor air handler (such as the Bosch BVA series) or an approved cased evaporator coil paired with a compatible furnace.\u003c\/li\u003e\n\u003cli\u003eElectrical supply: The 3.0 Ton model requires a 35 A breaker; the 5.0 Ton model requires a 50 A breaker on a dedicated 208\/230 V single-phase circuit with an outdoor disconnect switch.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate airflow clearance: maintain at least 30 cm (12 in) on the coil sides, 61 cm (24 in) on the service panel side, and 152 cm (60 in) above the top discharge fan.\u003c\/li\u003e\n\u003cli\u003eIn cold-climate regions where winter temperatures fall below −15 °C (5 °F), an auxiliary electric heat strip kit or backup gas furnace is required for peak heating demand.\u003c\/li\u003e\n\u003cli\u003eBosch specifies that installation and refrigerant piping must be performed by a qualified HVAC technician in compliance with local mechanical and electrical codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRequest a quote and we will confirm the right configuration, pricing and availability.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan the Bosch IDS be paired with standard non-communicating 24 V thermostats?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. Unlike proprietary communicating heat pumps, the Bosch IDS inverter logic is self-contained within the outdoor unit, allowing it to modulate seamlessly with any standard 24 V thermostat (including ecobee, Google Nest, or Honeywell).\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat refrigerant lineset sizes are required for the 3-ton system?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe system requires a 3\/8-inch liquid line and a 3\/4-inch suction line, pre-charged with R-410A refrigerant for up to 15 feet of lineset length.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eDoes the indoor air handler (BVA) support multi-position installation?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The BVA multi-position air handler can be configured for upflow, downflow, horizontal left, or horizontal right airflow orientations to match basement and attic duct transitions.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan auxiliary electric heat strips be installed for emergency backup?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. Optional 5 kW to 20 kW electric resistance heat strip kits can be installed directly into the BVA cabinet to provide emergency backup heating during extreme Canadian winter cold snaps.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat filter size does the BVA air handler use?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe air handler features an integrated slide-in filter rack that accommodates standard 1-inch or high-efficiency 4-inch deep pleated media air filters.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat clearance is required around the outdoor condenser in winter?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eElevate the outdoor condensing unit at least 12 to 18 inches (300 to 450 mm) above the ground on a sturdy equipment stand or wall bracket to keep the coil clear of Ontario snow drifts and ice accumulation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.bosch-homecomfort.com\/us\/media\/country_pool\/documents\/installation-manuals\/ids_premium_series_condensing_unit_iom_en_07.2026.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and operation manual — IDS Premium condensing unit (English) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.bosch-homecomfort.com\/us\/media\/country_pool\/documents\/installation-manuals\/ids_premium_series_air_handler_iom_en_02.2026.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and operation manual — IDS Premium air handler (English) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.bosch-homecomfort.com\/us\/media\/country_pool\/documents\/installation-manuals\/bosch_ids_bova20__bovc20_iom_12.2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and operation manual — BOVA20 \/ BOVC20 heat pump condenser (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.bosch-homecomfort.com\/us\/media\/country_pool\/service\/technical_guides\/bosch_ids2.0_bova-bva_service_manual_external_rev3.pdf\" target=\"_blank\" rel=\"noopener\"\u003eService manual — Bosch IDS 2.0 BOVA-BVA systems (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.bosch-homecomfort.com\/us\/media\/country_pool\/documents\/bosch_ids2.0_bova_iom_fr.pdf\" target=\"_blank\" rel=\"noopener\"\u003eManuel d'installation et d'utilisation — Bosch IDS 2.0 BOVA (Français) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.bosch-homecomfort.com\/us\/media\/country_pool\/documents\/energy-guides-for-water-heaters\/energy-guides-for-ac\/bova-36hdn1-m20g_bva-24wn1-m20.PDF\" target=\"_blank\" rel=\"noopener\"\u003eEnergy Guide — Bosch BOVA-36HDN1-M20G system ratings (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications from the Bosch Inverter Ducted Split (IDS) 2.0 product catalog, BOVA20 installation and operation manual, and AHRI matched ratings. Specifications are subject to change by the manufacturer. \u003ca href=\"https:\/\/www.bosch-homecomfort.com\/us\/media\/country_pool\/documents\/installation-manuals\/ids_premium_series_condensing_unit_iom_en_07.2026.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView the Bosch IDS Premium condenser manual (PDF)\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; Safety Notice:\u003c\/strong\u003e Inverter heat pump systems require professional sizing and installation by a licensed refrigeration\/HVAC technician and qualified electrician in compliance with manufacturer engineering specifications and provincial electrical\/building codes.\u003c\/p\u003e","brand":"Bosch","offers":[{"title":"3.0 Ton (covers 2.0 – 3.0 Ton)","offer_id":53964385124646,"sku":"BOVA-36HDN1-M20G","price":5490.0,"currency_code":"CAD","in_stock":true},{"title":"5.0 Ton (covers 4.0 – 5.0 Ton)","offer_id":53964385157414,"sku":"BOVA-60HDN1-M20G","price":6390.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/bosch_ids_1_system_04912ef6-e614-40b0-90f7-a61c9b564d77.jpg?v=1792997244"}],"url":"https:\/\/avlshop.ca\/collections\/frontpage.oembed","provider":"AVL Shop","version":"1.0","type":"link"}