{"title":"Gas Pool Heaters","description":null,"products":[{"product_id":"rheem-avia-hd-nitek-pool-heater","title":"Rheem AVIA HD NiTek Gas Pool Heater","description":"\u003cp\u003e\u003cstrong\u003eAn intelligent heavy-duty low-NOx gas pool and spa heater featuring proprietary NiTek nickel-alloy heat exchanger technology and integrated smart ecosystem automation.\u003c\/strong\u003e Engineered by Rheem and Raypak for harsh environments and modern saltwater pools, the AVIA HD NiTek series replaces standard copper with a specialized high-nickel alloy heat exchanger offering superior erosion resistance and scale protection. Available in 264,000 BTU\/h and 399,000 BTU\/h capacities for natural gas or propane, the AVIA HD delivers 84% thermal efficiency, a 2 ft by 2 ft pad footprint, straight-tube flow dynamics, and built-in Wi-Fi monitoring via the Raymote app.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNiTek nickel-alloy heat exchanger\u003c\/strong\u003e: engineered with 900% more nickel content than standard cupronickel, delivering maximum defense against corrosion, scale, and high-velocity water erosion in saltwater pools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented straight-tube design\u003c\/strong\u003e: continuous straight-tube geometry eliminates restrictive u-bends and helical coils, ensuring uniform heat transfer and simplified mechanical inspection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProTek Shield galvanic protection\u003c\/strong\u003e: factory-integrated sacrificial zinc anode module neutralizes galvanic currents between dissimilar metals, extending overall heat exchanger longevity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Wi-Fi \u0026amp; smart ecosystem control\u003c\/strong\u003e: on-board Raymote Wi-Fi enables real-time pool temperature management, automated heating schedules, and service diagnostics directly from a smartphone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary dry-contact relay\u003c\/strong\u003e: built-in terminal P9 AUX relay allows direct scheduling and automation of a single auxiliary pool component, such as an external pump, chlorinator, or water feature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-sided rotatable digital control display\u003c\/strong\u003e: high-contrast digital interface rotates in 90-degree increments to provide direct viewing regardless of plumbing pad orientation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSizing guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eThermal input\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eTypical pool surface area\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eTypical pool volume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRecommended application\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAVIA HD 264A\u003c\/th\u003e\n\u003ctd\u003e264,000 BTU\/h (77.4 kW)\u003c\/td\u003e\n\u003ctd\u003eUp to 600 sq ft\u003c\/td\u003e\n\u003ctd\u003eUp to 75,000 L (20,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eMid-size in-ground pools and rapid stand-alone spa heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAVIA HD 404A\u003c\/th\u003e\n\u003ctd\u003e399,000 BTU\/h (116.9 kW)\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 sq ft\u003c\/td\u003e\n\u003ctd\u003eUp to 130,000 L (34,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eLarge residential pools, exposed locations, and extended shoulder seasons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eAVIA HD 264A\u003c\/th\u003e\n\u003cth\u003eAVIA HD 404A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"3\"\u003eThermal Performance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal input rating\u003c\/td\u003e\n\u003ctd\u003e264,000 BTU\/h (77.4 kW)\u003c\/td\u003e\n\u003ctd\u003e399,000 BTU\/h (116.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal efficiency\u003c\/td\u003e\n\u003ctd\u003e84%\u003c\/td\u003e\n\u003ctd\u003e84%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissions profile\u003c\/td\u003e\n\u003ctd\u003eLow-NOx certified (\u0026lt; 40 ng\/J)\u003c\/td\u003e\n\u003ctd\u003eLow-NOx certified (\u0026lt; 40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exchanger alloy\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty NiTek nickel alloy straight tube\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty NiTek nickel alloy straight tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSaltwater compatibility\u003c\/td\u003e\n\u003ctd\u003eFully compatible with all residential salt chlorination systems\u003c\/td\u003e\n\u003ctd\u003eFully compatible with all residential salt chlorination systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic corrosion protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated ProTek Shield sacrificial anode module\u003c\/td\u003e\n\u003ctd\u003eIntegrated ProTek Shield sacrificial anode module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"3\"\u003eFuel \u0026amp; Gas Supply\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable factory fuels\u003c\/td\u003e\n\u003ctd\u003eNatural gas or Liquid propane (factory dedicated)\u003c\/td\u003e\n\u003ctd\u003eNatural gas or Liquid propane (factory dedicated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas pipe connection\u003c\/td\u003e\n\u003ctd\u003e3\/4 in. NPT female\u003c\/td\u003e\n\u003ctd\u003e3\/4 in. NPT female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet gas pressure (Natural Gas)\u003c\/td\u003e\n\u003ctd\u003e4.0 to 10.5 in. w.c.\u003c\/td\u003e\n\u003ctd\u003e4.0 to 10.5 in. w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet gas pressure (Propane)\u003c\/td\u003e\n\u003ctd\u003e11.0 to 13.0 in. w.c.\u003c\/td\u003e\n\u003ctd\u003e11.0 to 13.0 in. w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh altitude rating\u003c\/td\u003e\n\u003ctd\u003eCertified up to 1,371 m (4,500 ft) per CAN\/CGA-2.17-M91\u003c\/td\u003e\n\u003ctd\u003eCertified up to 1,371 m (4,500 ft) per CAN\/CGA-2.17-M91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"3\"\u003eWater Hydraulics\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater connection unions\u003c\/td\u003e\n\u003ctd\u003e2 in. CPVC buttress unions with slip adapters included\u003c\/td\u003e\n\u003ctd\u003e2 in. CPVC buttress unions with slip adapters included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating flow rate range\u003c\/td\u003e\n\u003ctd\u003e20 to 125 GPM (76 to 473 L\/min)\u003c\/td\u003e\n\u003ctd\u003e20 to 125 GPM (76 to 473 L\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal water bypass\u003c\/td\u003e\n\u003ctd\u003eFactory-installed automatic mechanical bypass\u003c\/td\u003e\n\u003ctd\u003eFactory-installed automatic mechanical bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e50 psi (345 kPa)\u003c\/td\u003e\n\u003ctd\u003e50 psi (345 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"3\"\u003eElectrical \u0026amp; Controls\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical supply voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC, 1-phase, 60 Hz, 4 A maximum\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC, 1-phase, 60 Hz, 4 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay \u0026amp; user interface\u003c\/td\u003e\n\u003ctd\u003eDigital touch controller, rotatable on 3 sides\u003c\/td\u003e\n\u003ctd\u003eDigital touch controller, rotatable on 3 sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart connectivity\u003c\/td\u003e\n\u003ctd\u003eIntegrated Wi-Fi with Raymote mobile app\u003c\/td\u003e\n\u003ctd\u003eIntegrated Wi-Fi with Raymote mobile app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary relay output\u003c\/td\u003e\n\u003ctd\u003eTerminal P9 AUX dry-contact relay\u003c\/td\u003e\n\u003ctd\u003eTerminal P9 AUX dry-contact relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"3\"\u003eDimensions \u0026amp; Weight\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet finish\u003c\/td\u003e\n\u003ctd\u003eCool dark gray metallic powder coat\u003c\/td\u003e\n\u003ctd\u003eCool dark gray metallic powder coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e590 mm (23.22 in.)\u003c\/td\u003e\n\u003ctd\u003e590 mm (23.22 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e772 mm (30.38 in.)\u003c\/td\u003e\n\u003ctd\u003e772 mm (30.38 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e828 mm (32.61 in.)\u003c\/td\u003e\n\u003ctd\u003e828 mm (32.61 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase footprint\u003c\/td\u003e\n\u003ctd\u003eFits standard 610 mm × 610 mm (24 × 24 in.) pad\u003c\/td\u003e\n\u003ctd\u003eFits standard 610 mm × 610 mm (24 × 24 in.) pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e61.2 kg (135 lb)\u003c\/td\u003e\n\u003ctd\u003e61.2 kg (135 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e70.2 kg (155 lb)\u003c\/td\u003e\n\u003ctd\u003e70.2 kg (155 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas lines and meter regulators must be verified and installed by a licensed gas technician in compliance with CSA B149.1 Natural gas and propane installation code.\u003c\/li\u003e\n\u003cli\u003eElectrical supply requires a dedicated 15 A 120 V or 240 V circuit compliant with Canadian Electrical Code (CSA C22.1) and bonded to the pool bonding grid with a minimum 6 AWG copper conductor.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum clearances from combustible surfaces: 6 in. rear, 6 in. sides, 24 in. front service access, and 48 in. overhead clearance for outdoor atmospheric venting.\u003c\/li\u003e\n\u003cli\u003eMaintain balanced water chemistry (pH 7.4–7.6, total alkalinity 80–120 ppm, calcium hardness 200–400 ppm) to ensure optimal operating efficiency.\u003c\/li\u003e\n\u003cli\u003eFor Canadian winter shutdown, drain water completely from both headers and internal heat exchanger tubes via the manifold drain plugs and blow clear with compressed air.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHave questions regarding pool heater BTU sizing, gas piping runs, or pad placement? Request a product quote and our equipment specialists will confirm equipment specifications for your property.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan the AVIA heater connect to Wi-Fi?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The AVIA features built-in Wi-Fi and Bluetooth enabled Raymote technology, enabling direct remote monitoring, timer control, and maintenance alerts via the Raymote mobile app without third-party automation hubs.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eIs the AVIA certified as Low-NOx?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The fan-assisted combustion system produces ultra-low NOx emissions below 14 ng\/J, exceeding Canadian and North American clean air emission requirements.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat are the outdoor installation clearance requirements?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eMaintain 12 inches (305 mm) of clearance on sides and rear from combustible walls, 24 inches (610 mm) of service access in front of the control panel, and unrestricted overhead clearance above the top exhaust louver.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan the AVIA be field-converted between Natural Gas and Propane?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eNo. The AVIA is factory-configured for either Natural Gas (EN models) or Propane (EP models) with calibrated burner orifices and gas valve springs. Field fuel conversions must only use official manufacturer conversion kits performed by a licensed gas technician.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eHow is the AVIA drained for winter in Ontario?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eShut off the gas supply and main electrical disconnect, remove the drain plugs from both the in\/out water header and return header, open pressure relief valves, and verify complete water drainage before frost arrives.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/RP-P-600-1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eTechnical brochure and sizing guide — Rheem AVIA HD NiTek pool heater (RP-P-600-1) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/100-10000111.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and operation manual — Rheem AVIA pool heater models 264A and 404A (100-10000111) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/RP-P-600-5.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDiagnostic and tool box guide — Rheem AVIA heater parts and troubleshooting (RP-P-600-5) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/241945.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaymote quick start guide — Wi-Fi connectivity and mobile app setup (241945) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications derived from Rheem\/Raypak AVIA HD NiTek technical brochure RP-P-600-1 REV E, AVIA Installation \u0026amp; Operation Manual P\/N 100-10000111 Rev 12, and Raymote Quick Start Guide 241945. Specifications are subject to change by the manufacturer. \u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/100-10000111.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView the AVIA Installation Manual (PDF)\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e","brand":"Rheem","offers":[{"title":"264K BTU\/h \/ Natural gas","offer_id":53964471828774,"sku":"018044","price":3680.0,"currency_code":"CAD","in_stock":true},{"title":"264K BTU\/h \/ Propane","offer_id":53964471861542,"sku":"018050","price":3680.0,"currency_code":"CAD","in_stock":true},{"title":"399K BTU\/h \/ Natural gas","offer_id":53964471894310,"sku":"018045","price":4240.0,"currency_code":"CAD","in_stock":true},{"title":"399K BTU\/h \/ Propane","offer_id":53964471927078,"sku":"018051","price":4240.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/rheem-avia-hd-nitek-gas-pool-heater.webp?v=1790691692"},{"product_id":"hayward-universal-h-series-pool-heater","title":"Hayward Universal H-Series Gas Pool Heater","description":"\u003cp\u003e\u003cstrong\u003eA compact, low-NOx gas pool and spa heater with a cupronickel heat exchanger in every size.\u003c\/strong\u003e The Hayward Universal H-Series heats in-ground pools and spas on natural gas or propane, with inputs from 150,000 to 399,900 BTU\/h. A forced-draft burner, hot surface ignition and a built-in header bypass make it a practical choice for new pools and for replacing an older heater.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCupronickel heat exchanger as standard\u003c\/strong\u003e — Hayward fits cupronickel tubes on every Universal H-Series model for resistance to salt water and pool chemicals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in low-loss bypass\u003c\/strong\u003e — Hayward's patented header bypass keeps the right flow through the heat exchanger, up to a maximum system flow of 473 L\/min (125 US gpm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForced-draft combustion\u003c\/strong\u003e — a combustion blower moves air through the burner at a set rate, so no high-wind stack is needed outdoors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow NOx emissions\u003c\/strong\u003e — meets the South Coast Air Quality Management District Rule 1146.2 low-NOx standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120 or 240 V power\u003c\/strong\u003e — factory wired for 240 V AC and field-convertible to 120 V AC with the supplied jumper; 5.5 A maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront-panel service access\u003c\/strong\u003e — routine service is done from the front, and junction boxes on both sides simplify electrical and automation wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChoosing a size\u003c\/h2\u003e\n\u003cp\u003eHayward sizes the heater by pool surface area. Its recommendation assumes a 17 °C (30 °F) temperature rise, an average wind of 5.6 km\/h (3.5 mph) and an elevation up to 610 m (2,000 ft). For an indoor pool, Hayward divides the surface area by three.\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eH150FD\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eH200FD\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eH250FD\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eH400FD\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePool surface area up to\u003c\/th\u003e\n\u003ctd\u003e41.8 m² (450 ft²)\u003c\/td\u003e\n\u003ctd\u003e55.7 m² (600 ft²)\u003c\/td\u003e\n\u003ctd\u003e69.7 m² (750 ft²)\u003c\/td\u003e\n\u003ctd\u003e111.5 m² (1,200 ft²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTime to heat a covered 1,514 L (400 US gal) spa by 17 °C (30 °F)\u003c\/th\u003e\n\u003ctd\u003e48 min\u003c\/td\u003e\n\u003ctd\u003e36 min\u003c\/td\u003e\n\u003ctd\u003e29 min\u003c\/td\u003e\n\u003ctd\u003e18 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003eModel comparison\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eH150FD\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eH200FD\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eH250FD\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eH400FD\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNatural gas model\u003c\/th\u003e\n\u003ctd\u003eH150FDN\u003c\/td\u003e\n\u003ctd\u003eH200FDN\u003c\/td\u003e\n\u003ctd\u003eH250FDN\u003c\/td\u003e\n\u003ctd\u003eH400FDN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePropane model\u003c\/th\u003e\n\u003ctd\u003eH150FDP\u003c\/td\u003e\n\u003ctd\u003eH200FDP\u003c\/td\u003e\n\u003ctd\u003eH250FDP\u003c\/td\u003e\n\u003ctd\u003eH400FDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas input\u003c\/th\u003e\n\u003ctd\u003e150,000 BTU\/h (44.0 kW)\u003c\/td\u003e\n\u003ctd\u003e199,900 BTU\/h (58.6 kW)\u003c\/td\u003e\n\u003ctd\u003e250,000 BTU\/h (73.3 kW)\u003c\/td\u003e\n\u003ctd\u003e399,900 BTU\/h (117.2 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermal efficiency\u003c\/th\u003e\n\u003ctd\u003e82.7%\u003c\/td\u003e\n\u003ctd\u003e83%\u003c\/td\u003e\n\u003ctd\u003e84%\u003c\/td\u003e\n\u003ctd\u003e84%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum water flow\u003c\/th\u003e\n\u003ctd\u003e76 L\/min (20 US gpm)\u003c\/td\u003e\n\u003ctd\u003e76 L\/min (20 US gpm)\u003c\/td\u003e\n\u003ctd\u003e95 L\/min (25 US gpm)\u003c\/td\u003e\n\u003ctd\u003e114 L\/min (30 US gpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e48.3 cm (19 in)\u003c\/td\u003e\n\u003ctd\u003e55.9 cm (22 in)\u003c\/td\u003e\n\u003ctd\u003e63.5 cm (25 in)\u003c\/td\u003e\n\u003ctd\u003e86.4 cm (34 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e61.2 kg (135 lb)\u003c\/td\u003e\n\u003ctd\u003e63.5 kg (140 lb)\u003c\/td\u003e\n\u003ctd\u003e74.8 kg (165 lb)\u003c\/td\u003e\n\u003ctd\u003e88.5 kg (195 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHayward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eUniversal H-Series Low NOx (FD models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct type\u003c\/th\u003e\n\u003ctd\u003eGas heater for in-ground pools and spas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas (…FDN) or propane (…FDP), set at the factory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCupronickel tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eSilicon nitride hot surface ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCombustion\u003c\/th\u003e\n\u003ctd\u003eForced draft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eWater connections and flow\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePlumbing connections\u003c\/th\u003e\n\u003ctd\u003e2 in × 2½ in CPVC unions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum water flow\u003c\/th\u003e\n\u003ctd\u003e473 L\/min (125 US gpm), all models; install a manual bypass valve above this flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBypass\u003c\/th\u003e\n\u003ctd\u003eIntegral low-loss header bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eGas supply\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection at heater\u003c\/th\u003e\n\u003ctd\u003e¾ in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet pressure, natural gas\u003c\/th\u003e\n\u003ctd\u003e4.5–10.5 in w.c. (1.12–2.62 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet pressure, propane\u003c\/th\u003e\n\u003ctd\u003e10.0–13.0 in w.c. (2.49–3.24 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManifold pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas 1.8–2.2 in w.c.; propane 6.8–7.0 in w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAltitude as shipped\u003c\/th\u003e\n\u003ctd\u003eUp to 610 m (2,000 ft); high-altitude kit FDXLHAK1931 above that\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e120 or 240 V AC, 60 Hz, single phase (factory wired for 240 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum current\u003c\/th\u003e\n\u003ctd\u003e5.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended circuit protection\u003c\/th\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDimensions and clearances\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeight × depth\u003c\/th\u003e\n\u003ctd\u003e61.0 × 74.9 cm (24 × 29½ in), all models; width per model above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearance, front\u003c\/th\u003e\n\u003ctd\u003e46 cm (18 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearance, back\u003c\/th\u003e\n\u003ctd\u003e15 cm (6 in); 30 cm (12 in) in front of vinyl siding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearance, sides\u003c\/th\u003e\n\u003ctd\u003e30 cm (12 in) on the water-connection side, 15 cm (6 in) on the opposite side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearance, top\u003c\/th\u003e\n\u003ctd\u003eUnobstructed outdoors; 91 cm (36 in) indoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCertification\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDesign certification\u003c\/th\u003e\n\u003ctd\u003eETL (USA and Canada); design compliant with ANSI Z21.56 and CSA 4.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes in Canada\u003c\/th\u003e\n\u003ctd\u003eCAN\/CSA B149.1 (gas) and CSA C22.1 Canadian Electrical Code, Part 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmissions\u003c\/th\u003e\n\u003ctd\u003eSCAQMD Rule 1146.2 (low NOx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eChoose the size from your pool's surface area (see the table above); a pool cover reduces heat loss and heating time.\u003c\/li\u003e\n\u003cli\u003eCheck that your gas meter or propane tank can supply the heater's full input on top of your other gas appliances. Propane tanks must be outdoors and sized for vaporization at the lowest expected temperature.\u003c\/li\u003e\n\u003cli\u003eYour pump must deliver at least the model's minimum flow, with a dirty filter and any in-floor cleaner running. Above 473 L\/min (125 US gpm) a manual bypass valve is required.\u003c\/li\u003e\n\u003cli\u003ePlan a dedicated 120 V or 240 V circuit with 15 A protection, and a gas shut-off valve outside the cabinet within 1.8 m (6 ft) of the heater.\u003c\/li\u003e\n\u003cli\u003eIndoor installations need Hayward's indoor vent kit for the heater size; installations above 610 m (2,000 ft) need the high-altitude kit.\u003c\/li\u003e\n\u003cli\u003eFuel is set at the factory. Changing between natural gas and propane needs a Hayward conversion kit installed by a qualified service agency, where local codes allow it.\u003c\/li\u003e\n\u003cli\u003eHayward specifies installation by a qualified technician in line with CAN\/CSA B149.1, the Canadian Electrical Code and local codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot sure which size suits your pool? Request a quote and we will confirm the right configuration, pricing and availability.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat heat exchanger material is used in the Hayward Universal H-Series?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe Universal H-Series features a cupronickel finned-tube heat exchanger that provides superior corrosion resistance against pool chemistry fluctuations, high flow velocities, and saltwater chlorination systems compared to standard copper.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat is the thermal efficiency rating of the H-Series gas heater?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe Hayward Universal H-Series achieves an 83% to 84% thermal efficiency rating, utilizing forced-draft combustion and insulated ceramic combustion chambers to maximize heat transfer to pool water.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat electrical connection does the heater require?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe internal electronic ignition and digital control circuitry feature a universal dual-voltage transformer configured for 120 V or 240 V single-phase 60 Hz electrical supply.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat water flow rate is needed for the H250FD?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe H250FD (250,000 BTU\/h) requires a minimum water flow rate of 30 GPM (114 L\/min) and supports maximum flow up to 125 GPM (473 L\/min) using its internal automatic bypass valve.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat gas supply pressure is required for natural gas operation?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eNatural gas models require an incoming manifold supply pressure between 5.0 inches and 10.5 inches water column (W.C.). A dedicated licensed gas technician must measure supply pressure under full firing load per CSA B149.1.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan this heater be converted from natural gas to propane?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. Hayward provides official certified conversion kits containing factory orifices and gas valve spring regulator parts. Conversions must be completed and tagged by a licensed gas technician.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat plumbing pipe size connects to the water header?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe heater includes 2-inch by 2.5-inch CPVC union plumbing nuts that connect directly to standard 2-inch Schedule 40 PVC swimming pool plumbing.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eDoes the heater produce low emissions?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The forced-draft low-NOx combustion system complies with clean air standards, reducing nitrogen oxide emissions below 40 ng\/J.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan the heater be installed indoors?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. When installed indoors, an official Hayward indoor direct-vent adapter kit and ULC-S636 approved Category III\/IV venting must be installed following local building codes and CSA B149.1.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eHow is the Hayward H-Series winterized for Canadian winter?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eTurn off the gas supply shutoff valve and power disconnect. Remove both drain plugs located on the front and rear plastic water headers. Disconnect CPVC union collars, and blow low-pressure compressed air through the exchanger to remove all trapped water.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/commerce.hayward-pool-assets.com\/magento\/akeneo\/H250FDN\/manuals\/51300004201RevE_3d59.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOwner's manual — Universal H-Series (H150FD–H400FD), 51300004201 Rev E (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/commerce.hayward-pool-assets.com\/magento\/akeneo\/H250FDN\/manuals\/uhs_qrg_e5bc.pdf\" target=\"_blank\" rel=\"noopener\"\u003eQuick reference guide — Universal H-Series (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/commerce.hayward-pool-assets.com\/magento\/akeneo\/H250FDN\/literature\/LITUHS22C_Universal_HSeries_Brochure_Bilingual_6298.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure — Universal H-Series (Hayward Canada, bilingual, LITUHS22C) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/commerce.hayward-pool-assets.com\/magento\/akeneo\/H250FDN\/literature\/LITUHSBRO23_Universal_H_Series_Brochure_DIGITAL_320f.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBrochure — Universal H-Series (LITUHSBRO23) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/commerce.hayward-pool-assets.com\/magento\/akeneo\/H250FDN\/manuals\/IndoorVentKitInstructions_2021_64e3.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndoor vent kit instructions — Universal H-Series (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/commerce.hayward-pool-assets.com\/magento\/akeneo\/H250FDN\/literature\/CuproNickelSellSheet_b2bc.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCupronickel heat exchanger sell sheet — Hayward (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/commerce.hayward-pool-assets.com\/magento\/akeneo\/H250FDN\/line_drawings\/UniversalH_SeriesLowNOx_de2d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDimensional drawing — Universal H-Series Low NOx (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications from Hayward's In-Ground Pool\/Spa Gas Heaters owner's manual (51300004201 Rev E), Hayward Canada product pages for each model, and the Universal H-Series bilingual brochure (LITUHS22C, 2022) for sizing and spa heat-up times. kW and metric values converted from Hayward's imperial figures. Specifications are subject to change by the manufacturer. \u003ca href=\"https:\/\/commerce.hayward-pool-assets.com\/magento\/akeneo\/H250FDN\/manuals\/51300004201RevE_3d59.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView the Hayward Universal H-Series owner's manual (PDF)\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e","brand":"Hayward","offers":[{"title":"150,000 BTU\/h \/ Natural gas","offer_id":53964411601190,"sku":"H150FDN","price":3280.0,"currency_code":"CAD","in_stock":true},{"title":"150,000 BTU\/h \/ Propane","offer_id":53964411633958,"sku":"H150FDP","price":3280.0,"currency_code":"CAD","in_stock":true},{"title":"200,000 BTU\/h \/ Natural gas","offer_id":53964411666726,"sku":"H200FDN","price":3830.0,"currency_code":"CAD","in_stock":true},{"title":"200,000 BTU\/h \/ Propane","offer_id":53964411699494,"sku":"H200FDP","price":3830.0,"currency_code":"CAD","in_stock":true},{"title":"250,000 BTU\/h \/ Natural gas","offer_id":53964411732262,"sku":"H250FDN","price":3980.0,"currency_code":"CAD","in_stock":true},{"title":"250,000 BTU\/h \/ Propane","offer_id":53964411765030,"sku":"H250FDP","price":3980.0,"currency_code":"CAD","in_stock":true},{"title":"400,000 BTU\/h \/ Natural gas","offer_id":53964411797798,"sku":"H400FDN","price":5180.0,"currency_code":"CAD","in_stock":true},{"title":"400,000 BTU\/h \/ Propane","offer_id":53964411830566,"sku":"H400FDP","price":5180.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/hayward-universal-h-series-pool-heater.png?v=1790573371"},{"product_id":"pentair-mastertemp-gas-pool-heater","title":"Pentair MasterTemp High-Performance Gas Pool Heater","description":"\u003cp\u003e\u003cstrong\u003eA compact, high-efficiency gas pool heater engineered with a tough composite exterior that never rusts.\u003c\/strong\u003e The Pentair MasterTemp series delivers rapid heat-up times and reliable temperature regulation for in-ground pools and spa combinations. Featuring a pre-mixed air and gas combustion system, fully digital rotating display, and certified low-NOx emissions, MasterTemp provides dependable heating performance across Canadian seasonal temperature swings.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-duty rustproof housing\u003c\/strong\u003e — tough composite exterior enclosure withstands severe outdoor weather conditions, coastal moisture, and chemical exposure without corrosion or fading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-mixed air and gas combustion\u003c\/strong\u003e — sealed combustion chamber with electric blower mixes fuel and air for efficient 84% thermal efficiency and quiet burner operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotating digital control panel\u003c\/strong\u003e — intuitive push-button interface rotates to three different positions for convenient viewing and operation from any equipment pad orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-NOx certified emissions\u003c\/strong\u003e — clean-burning combustion system meets and exceeds stringent air quality standards, including SCAQMD Rule 1146.2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot surface ignition\u003c\/strong\u003e — electronic ignition provides reliable starting without a standing pilot light, reducing overall fuel consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic indicator lights\u003c\/strong\u003e — control board includes system monitoring LEDs for water pressure switch, high limit sensors, thermal regulator, and flame detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eMasterTemp High Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n\u003ctd\u003eGas-fired pool and spa heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermal efficiency\u003c\/th\u003e\n\u003ctd\u003e84%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable thermal capacities\u003c\/th\u003e\n\u003ctd\u003e175,000 \/ 250,000 \/ 300,000 \/ 400,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel types\u003c\/th\u003e\n\u003ctd\u003eNatural Gas (NG) or Liquid Propane (LP) dedicated factory configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eFinned copper tube heat exchanger with cupro-nickel option (HD models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition system\u003c\/th\u003e\n\u003ctd\u003eHot Surface Ignition (HSI) electronic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCombustion type\u003c\/th\u003e\n\u003ctd\u003eFan-assisted forced draft pre-mixed combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eRotating digital LED display with dual temperature settings (Pool and Spa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWater connection size\u003c\/th\u003e\n\u003ctd\u003e2 in. CPVC slip unions included (reversible header for left or right plumbing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended flow rate (175–250)\u003c\/th\u003e\n\u003ctd\u003e20 to 120 GPM (76 to 454 L\/min); external bypass required above 120 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended flow rate (300–400)\u003c\/th\u003e\n\u003ctd\u003e40 to 120 GPM (151 to 454 L\/min); external bypass required above 120 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas supply connection\u003c\/th\u003e\n\u003ctd\u003e3\/4 in. NPT internal thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum natural gas supply pressure\u003c\/th\u003e\n\u003ctd\u003e4.0 in. w.c. (1.0 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum natural gas supply pressure\u003c\/th\u003e\n\u003ctd\u003e10.5 in. w.c. (2.6 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum propane supply pressure\u003c\/th\u003e\n\u003ctd\u003e11.0 in. w.c. (2.7 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum propane supply pressure\u003c\/th\u003e\n\u003ctd\u003e13.0 in. w.c. (3.2 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical requirements\u003c\/th\u003e\n\u003ctd\u003e120 V AC, 60 Hz, 3 A or 240 V AC, 60 Hz, 1.5 A single phase (field switchable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCabinet construction\u003c\/th\u003e\n\u003ctd\u003eCorrosion-resistant molded thermoplastic structural composite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVenting configuration\u003c\/th\u003e\n\u003ctd\u003eOutdoor atmospheric direct discharge or indoor Category I \/ III venting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W × D × H)\u003c\/th\u003e\n\u003ctd\u003e533 × 533 × 711 mm (21.0 × 21.0 × 28.0 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating weight (175 \/ 250)\u003c\/th\u003e\n\u003ctd\u003e53.5 kg (118 lb) \/ 57.2 kg (126 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating weight (300 \/ 400)\u003c\/th\u003e\n\u003ctd\u003e61.7 kg (136 lb) \/ 64.9 kg (143 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCSA certified to ANSI Z21.56 \/ CSA 4.7 standard for gas-fired pool heaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas line sizing must be verified by a licensed gas technician in accordance with Canadian gas installation codes (CSA B149.1) to maintain required flow under full load.\u003c\/li\u003e\n\u003cli\u003eThe heater must be mounted on a level, non-combustible base with minimum clearances: 15 cm (6 in.) on sides, 122 cm (48 in.) above the top for outdoor discharge, and 15 cm (6 in.) at the rear.\u003c\/li\u003e\n\u003cli\u003eMaintain balanced water chemistry (pH 7.4–7.6, total alkalinity 80–120 ppm, calcium hardness 200–400 ppm) to protect heat exchanger surfaces from scale and corrosion.\u003c\/li\u003e\n\u003cli\u003eWhen installing above 120 GPM total filter pump flow, an external manual bypass valve assembly must be installed to prevent excessive heat exchanger erosion.\u003c\/li\u003e\n\u003cli\u003eFull winterization (draining header plugs and heat exchanger manifold) is required prior to freezing temperatures in Canadian climates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eQuestions about gas line sizing or equipment pad layout? Contact our technical team for assistance.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat is the thermal efficiency of the MasterTemp?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe MasterTemp achieves up to 84% thermal efficiency, meeting air-quality low-NOx emission standards with a fully premixed air and gas combustion blower system.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat gas line pressure is required for natural gas models?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eIncoming natural gas pressure must be between 4.0 inches W.C. minimum and 14.0 inches W.C. maximum during full burner operation to avoid flame rollout or pressure drop.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan the MasterTemp be automated with Pentair IntelliTouch or EasyTouch?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The heater has standard 2-wire automation connections compatible with Pentair automation panels, IntelliCenter, and third-party remote control systems.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat pad clearance is required around the unit?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eMaintain 6 inches (150 mm) of clearance on the back and non-plumbed side, 12 inches (300 mm) on the plumbing side, 18 inches (450 mm) for front control access, and unobstructed overhead exhaust.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eHow should the MasterTemp be drained for freezing weather?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eShut off electrical power and gas valve. Remove the drain plugs from the water header, open the manual bypass, disconnect the union fittings, and use compressed air to expel any water remaining in the tubes.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp\/manual\/mastertemp-heater-manual-english.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and user's guide — Pentair MasterTemp pool and spa heater (English) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp\/manual\/archive\/Pentair%20MasterTemp%20Heater%20Submittal%20Data.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct specification and submittal data sheet — Pentair MasterTemp series (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications compiled from official Pentair MasterTemp High Performance Heater Installation and User's Guide (P\/N 472592) and MasterTemp engineering specification sheet. All specifications are subject to manufacturer verification. \u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp\/manual\/mastertemp-heater-manual-english.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView the Pentair MasterTemp manual (PDF)\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; Safety Notice:\u003c\/strong\u003e Gas pool heaters must be installed by a licensed gas technician (TSSA certified in Ontario) in accordance with the manufacturer's manual and applicable venting and fuel codes.\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"175,000 BTU\/h \/ Natural gas","offer_id":53973654536486,"sku":"460730","price":3450.0,"currency_code":"CAD","in_stock":true},{"title":"175,000 BTU\/h \/ Propane","offer_id":53973654569254,"sku":"460731","price":3450.0,"currency_code":"CAD","in_stock":true},{"title":"250,000 BTU\/h \/ Natural gas","offer_id":53973654602022,"sku":"460732","price":3780.0,"currency_code":"CAD","in_stock":true},{"title":"250,000 BTU\/h \/ Propane","offer_id":53973654634790,"sku":"460733","price":3780.0,"currency_code":"CAD","in_stock":true},{"title":"300,000 BTU\/h \/ Natural gas","offer_id":53973654667558,"sku":"460734","price":4290.0,"currency_code":"CAD","in_stock":true},{"title":"300,000 BTU\/h \/ Propane","offer_id":53973654700326,"sku":"460735","price":4290.0,"currency_code":"CAD","in_stock":true},{"title":"400,000 BTU\/h \/ Natural gas","offer_id":53973654733094,"sku":"460736","price":5089.0,"currency_code":"CAD","in_stock":true},{"title":"400,000 BTU\/h \/ Propane","offer_id":53973654765862,"sku":"460737","price":5180.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/pentair-mastertemp-gas-pool-heater_79440c51-cf5a-4ca6-95b2-e2c9997e8de7.png?v=1790688811"},{"product_id":"jandy-jxi-low-nox-gas-pool-heater","title":"Jandy JXi Low-NOx Gas Pool \u0026 Spa Heater","description":"\u003cp\u003e\u003cstrong\u003eAn ultra-compact, high-efficiency gas pool heater engineered with a space-saving 2' × 2' footprint and lightweight design.\u003c\/strong\u003e The Jandy JXi series sets a benchmark in equipment pad flexibility, weighing up to 38% less than traditional gas heaters. Equipped with an 84% thermal efficiency copper heat exchanger, digital diagnostic interface, and factory plumbing configuration ready for VersaFlo integrated bypass, JXi delivers high-output pool heating with minimal hydraulic resistance.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-compact 2' × 2' footprint\u003c\/strong\u003e — fits onto compact equipment pads and provides direct plumbing alignment for seamless replacement of older MasterTemp and Max-E-Therm units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersaFlo integrated bypass compatible\u003c\/strong\u003e — factory-designed for the optional VersaFlo automated flow bypass, diverting unused water flow away from the heat exchanger to reduce pump electrical consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh thermal efficiency\u003c\/strong\u003e — 84% thermal efficiency rating maximizes heat transfer into the swimming pool while minimizing gas fuel consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-NOx combustion blower\u003c\/strong\u003e — forced-draft fan combustion ensures clean, low-emission operation meeting strict environmental air quality standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital user interface\u003c\/strong\u003e — top-mounted control panel features an easy-to-read numeric display, push-button temperature adjustments, and self-diagnostic error reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAquaLink automation ready\u003c\/strong\u003e — connects directly to Jandy AquaLink and iAquaLink automation control systems via RS-485 4-wire communication cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eJandy (Fluidra)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eJXi Pro Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n\u003ctd\u003eLow-NOx gas-fired pool and spa heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermal efficiency\u003c\/th\u003e\n\u003ctd\u003e84%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable thermal capacities\u003c\/th\u003e\n\u003ctd\u003e200,000 \/ 260,000 \/ 400,000 BTU\/h (399,000 BTU\/h actual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel configurations\u003c\/th\u003e\n\u003ctd\u003eNatural Gas (N suffix) or Liquid Propane (P suffix) dedicated factory models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eFin-tube copper heat exchanger with polymer headers (cupro-nickel available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBypass system\u003c\/th\u003e\n\u003ctd\u003eInternal automatic hydraulic bypass with optional VersaFlo motorized bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition method\u003c\/th\u003e\n\u003ctd\u003eDirect spark electronic ignition with flame rectification sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl interface\u003c\/th\u003e\n\u003ctd\u003eDigital LCD display with dual temperature setpoints (Pool and Spa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePlumbing connections\u003c\/th\u003e\n\u003ctd\u003e2 in. \/ 2-1\/2 in. universal CPVC unions included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended flow rate (200–260)\u003c\/th\u003e\n\u003ctd\u003e30 to 100 GPM (114 to 379 L\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended flow rate (400)\u003c\/th\u003e\n\u003ctd\u003e30 to 120 GPM (114 to 454 L\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection size\u003c\/th\u003e\n\u003ctd\u003e3\/4 in. NPT connection (up to 200–260) \/ 3\/4 in. or 1 in. NPT (400 depending on run length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNatural gas supply pressure\u003c\/th\u003e\n\u003ctd\u003e5.0 to 10.5 in. w.c. (1.2 to 2.6 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePropane supply pressure\u003c\/th\u003e\n\u003ctd\u003e10.0 to 14.0 in. w.c. (2.5 to 3.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical requirements\u003c\/th\u003e\n\u003ctd\u003e120 V AC, 60 Hz, 2 A or 240 V AC, 60 Hz, 1 A field switchable single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePowder-coated galvanized steel with polymer top cap and base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExhaust venting\u003c\/th\u003e\n\u003ctd\u003eOutdoor top atmospheric exhaust with optional indoor Category I \/ III venting kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W × D × H)\u003c\/th\u003e\n\u003ctd\u003e582 × 561 × 673 mm (22.9 × 22.1 × 26.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating weight (200 \/ 260 \/ 400)\u003c\/th\u003e\n\u003ctd\u003e53.1 kg (117 lb) \/ 54.4 kg (120 lb) \/ 57.6 kg (127 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCSA certified to ANSI Z21.56 \/ CSA 4.7 pool heater standard; SCAQMD Rule 1146.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA licensed gas technician must calculate supply line diameter and gas meter regulator capacity according to Canadian gas installation codes (CSA B149.1).\u003c\/li\u003e\n\u003cli\u003eMaintain minimum clearances from combustible surfaces: 15 cm (6 in.) sides, 122 cm (48 in.) overhead vertical clearance for outdoor flue discharge, and 15 cm (6 in.) rear.\u003c\/li\u003e\n\u003cli\u003eWhen retrofitting existing Pentair MasterTemp or Max-E-Therm pads, plumbing inlet and outlet centerlines align with minimal pipe reconfiguration.\u003c\/li\u003e\n\u003cli\u003eVerify that total pool filter flow remains between 30 and 120 GPM; high-flow pump installations above 120 GPM require an external plumbing bypass loop.\u003c\/li\u003e\n\u003cli\u003eComplete winterization is required in Ontario before the first hard freeze by removing header drain plugs and blowing residual moisture clear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHave questions about pad sizing or automation compatibility? Contact our technical team for guidance.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eDoes the Jandy JXi connect to AquaLink automation?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The digital control board connects directly to Jandy AquaLink RS, PDA, and iQPUMP interfaces via four-wire RS-485 digital communication or standard 2-wire dry contact relays.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat are the vent clearances for outdoor installation?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eMaintain 12 inches (305 mm) clearance around the cabinet perimeter from non-combustible surfaces and 48 inches (1,219 mm) of open vertical exhaust clearance above the top exhaust grille.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat gas supply line size is required?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eDepending on distance from the gas meter, natural gas models require a 3\/4-inch to 1-1\/4-inch gas line with supply pressure between 5.0 and 10.5 inches W.C. per CSA B149.1.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan the unit be installed indoors?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. Indoor installations require an official Jandy draft hood or direct vent adapter and Category I or III venting according to Canadian gas installation standards.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat is the winterization procedure for the Jandy JXi?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eShut off the electrical disconnect switch and gas valve. Remove the drain plug from the header manifold, unthread the pressure switch tubing, disconnect the 2-inch unions, and blow through the heat exchanger with compressed air.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.jandy.com\/-\/media\/zodiac\/global\/downloads\/h\/h0574300.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and operation manual — Jandy JXi pool and spa heater (H0574300) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.jandy.com\/-\/media\/zodiac\/global\/downloads\/sa\/sa6302.pdf\" target=\"_blank\" rel=\"noopener\"\u003eTechnical sell sheet — Jandy JXi series pool heater (SA6302) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications compiled from Jandy JXi Gas-Fired Pool and Spa Heater Installation and Operation Manual (Document H0574300) and Jandy JXi Technical Sell Sheet (SA6302). Specifications are subject to verification by manufacturer engineering documentation. \u003ca href=\"https:\/\/www.jandy.com\/-\/media\/zodiac\/global\/downloads\/h\/h0574300.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView the Jandy JXi installation manual (PDF)\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e","brand":"Jandy","offers":[{"title":"200,000 BTU\/h \/ Natural gas","offer_id":53973655486758,"sku":"JXi200N","price":3950.0,"currency_code":"CAD","in_stock":true},{"title":"200,000 BTU\/h \/ Propane","offer_id":53973655519526,"sku":"JXi200P","price":3950.0,"currency_code":"CAD","in_stock":true},{"title":"260,000 BTU\/h \/ Natural gas","offer_id":53973655552294,"sku":"JXi260N","price":4140.0,"currency_code":"CAD","in_stock":true},{"title":"260,000 BTU\/h \/ Propane","offer_id":53973655585062,"sku":"JXi260P","price":3780.0,"currency_code":"CAD","in_stock":true},{"title":"400,000 BTU\/h \/ Natural gas","offer_id":53973655617830,"sku":"JXi400N","price":4580.0,"currency_code":"CAD","in_stock":true},{"title":"400,000 BTU\/h \/ Propane","offer_id":53973655650598,"sku":"JXi400P","price":4580.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/jandy-jxi-low-nox-gas-pool-heater_21da2efe-91e8-44f1-bbc8-9289fecd6d9e.png?v=1790688833"},{"product_id":"raypak-digital-gas-pool-heater","title":"Raypak Digital Gas Pool \u0026 Spa Heater","description":"\u003cp\u003e\u003cstrong\u003eA rugged atmospheric gas pool heater built with heavy-gauge galvanized steel and advanced ProTek Shield galvanic protection.\u003c\/strong\u003e The Raypak Digital Atmospheric series delivers proven heating reliability across in-ground residential swimming pools and commercial spas. Engineered with integral non-corrosive polymer headers, finned copper tube heat exchanger, and microprocessor-controlled temperature regulation, the 206A through 406A models provide dependable performance and straightforward serviceability across Canada's seasonal climate.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProTek Shield galvanic protection\u003c\/strong\u003e — integrated sacrificial anode module protects the copper heat exchanger against aggressive water chemistry and galvanic erosion caused by modern salt chlorinators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor digital thermostat\u003c\/strong\u003e — high-contrast LCD controller provides precise pool and spa dual-temperature adjustment, clear operational readouts, and plain-language diagnostic fault codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosion-resistant steel cabinet\u003c\/strong\u003e — heavy-gauge galvanized steel exterior receives a durable polyester powder-coat finish that withstands extreme weather exposure, UV sunlight, and rain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntermittent spark ignition\u003c\/strong\u003e — electronic pilot ignition system ignites fuel only on demand, eliminating the continuous fuel consumption of conventional standing pilot systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-corrosive polymer headers\u003c\/strong\u003e — engineered polymer header design optimizes internal water flow dynamics and resists rust and mineral scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-flow capability\u003c\/strong\u003e — internal mechanical bypass automatically balances water velocity through the finned tubes, supporting standard residential pump flow rates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSizing guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eInput rating\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eTypical pool surface area\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eTypical pool volume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e206A\u003c\/th\u003e\n\u003ctd\u003e199,500 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eUp to 450 sq ft\u003c\/td\u003e\n\u003ctd\u003eUp to 55,000 L (14,500 US gal)\u003c\/td\u003e\n\u003ctd\u003eStandalone spas and smaller in-ground pools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e266A\u003c\/th\u003e\n\u003ctd\u003e266,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eUp to 600 sq ft\u003c\/td\u003e\n\u003ctd\u003eUp to 75,000 L (20,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eStandard residential in-ground pools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e336A\u003c\/th\u003e\n\u003ctd\u003e332,500 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eUp to 750 sq ft\u003c\/td\u003e\n\u003ctd\u003eUp to 95,000 L (25,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eMid-to-large pools and faster spa heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e406A\u003c\/th\u003e\n\u003ctd\u003e399,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 sq ft\u003c\/td\u003e\n\u003ctd\u003eUp to 130,000 L (34,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eLarge pools, exposed locations, and extended shoulder seasons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak (A Rheem Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eDigital Atmospheric (206A–406A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n\u003ctd\u003eGas-fired atmospheric pool and spa heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermal efficiency\u003c\/th\u003e\n\u003ctd\u003e82%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable thermal capacities\u003c\/th\u003e\n\u003ctd\u003e199,500 \/ 266,000 \/ 332,500 \/ 399,000 BTU\/h input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel types\u003c\/th\u003e\n\u003ctd\u003eNatural Gas (NG) or Liquid Propane (LP) factory dedicated models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eFinned copper tubing with integral floating header return bends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCorrosion protection\u003c\/th\u003e\n\u003ctd\u003eProTek Shield sacrificial zinc anode module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCombustion type\u003c\/th\u003e\n\u003ctd\u003eAtmospheric draft with multi-port stainless steel burners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition system\u003c\/th\u003e\n\u003ctd\u003eDirect electronic spark ignition (IID) with flame sense rod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl interface\u003c\/th\u003e\n\u003ctd\u003eDigital LCD display with dual temperature setpoints (Pool and Spa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWater plumbing connections\u003c\/th\u003e\n\u003ctd\u003e2 in. CPVC slip flanged connections included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended flow rate (206A–406A)\u003c\/th\u003e\n\u003ctd\u003e20 to 125 GPM (76 to 473 L\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection size\u003c\/th\u003e\n\u003ctd\u003e3\/4 in. NPT internal gas supply connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNatural gas supply pressure\u003c\/th\u003e\n\u003ctd\u003e5.0 to 10.5 in. w.c. (1.2 to 2.6 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePropane supply pressure\u003c\/th\u003e\n\u003ctd\u003e11.0 to 13.0 in. w.c. (2.7 to 3.2 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical power\u003c\/th\u003e\n\u003ctd\u003e120 V AC or 240 V AC, 60 Hz, 1 A field selectable connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExhaust venting\u003c\/th\u003e\n\u003ctd\u003eOutdoor atmospheric top hood (included) or indoor D-2 draft hood kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCabinet finish\u003c\/th\u003e\n\u003ctd\u003ePolyester powder-coated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W × D × H) 206A\u003c\/th\u003e\n\u003ctd\u003e508 × 711 × 978 mm (20.0 × 28.0 × 38.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W × D × H) 266A\u003c\/th\u003e\n\u003ctd\u003e584 × 711 × 978 mm (23.0 × 28.0 × 38.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W × D × H) 336A\u003c\/th\u003e\n\u003ctd\u003e648 × 711 × 978 mm (25.5 × 28.0 × 38.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions (W × D × H) 406A\u003c\/th\u003e\n\u003ctd\u003e737 × 711 × 978 mm (29.0 × 28.0 × 38.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating weight (206A \/ 266A)\u003c\/th\u003e\n\u003ctd\u003e57 kg (126 lb) \/ 63 kg (139 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating weight (336A \/ 406A)\u003c\/th\u003e\n\u003ctd\u003e70 kg (154 lb) \/ 78 kg (172 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCSA design certified to ANSI Z21.56 \/ CSA 4.7 pool heater standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas piping must be sized by a licensed gas technician in compliance with CSA B149.1 Natural gas and propane installation code.\u003c\/li\u003e\n\u003cli\u003eAtmospheric units require clear outdoor vertical discharge with at least 122 cm (48 in.) overhead clearance from overhangs and trees.\u003c\/li\u003e\n\u003cli\u003eThe heater must be installed on a level, fire-rated non-combustible base or approved combustible floor shield.\u003c\/li\u003e\n\u003cli\u003eInspect and service the ProTek Shield anode periodically to maintain active galvanic corrosion protection across pool seasons.\u003c\/li\u003e\n\u003cli\u003eBefore winter freezes occur, drain water completely from both headers and the internal heat exchanger manifold using the drain petcocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHave questions about model sizing or gas supply capacity? Contact our technical team for assistance.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat cabinet finish is used on the Raypak Digital atmospheric heater?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe Raypak Digital features a galvanized steel cabinet with a multi-stage polyester powder-coat finish designed to withstand harsh outdoor weathering and corrosive pool environments.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eHow does the Raypak ProTek Shield protect the heater?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eProTek Shield is an integrated sacrificial galvanic zinc anode module installed directly in the water header that corrodes preferentially, shielding the finned-tube heat exchanger from galvanic corrosion.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eDoes the Raypak atmospheric heater require an electrical connection?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe digital model uses a 120\/240 V single-phase electrical supply for the micro-processor control board and electronic direct spark ignition. Millivolt models are also available that operate without external electricity.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat water flow rate is needed for Raypak Digital heaters (206k to 406k BTU)?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe heater requires a minimum flow rate of 25 GPM to 40 GPM (depending on model) and includes an internal automatic bypass valve handling flow up to 125 GPM (473 L\/min).\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat gas supply pressure is required for natural gas operation?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eNatural gas models require an incoming gas pressure of 5.0 inches W.C. minimum to 10.5 inches W.C. maximum under full operating load per CSA B149.1 standards.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat digital controls are built into the Raypak heater?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe heater features an on-board dual-thermostat LCD digital control that allows separate precise temperature setpoints for swimming pools and spas with self-diagnostic error reporting.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan the Raypak Digital be converted from natural gas to propane?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. Factory-approved field conversion kits are available from the manufacturer. Fuel conversions must only be performed by a licensed gas technician.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat are the plumbing connections on the Raypak Digital?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe heater includes 2-inch CPVC polymer union fittings that solvent-weld directly to rigid Schedule 40 PVC pool piping.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat outdoor clearance is required for the atmospheric heater?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eMaintain 12 inches (305 mm) clearance from side and rear walls, 24 inches (610 mm) for front service access, and at least 36 inches (914 mm) of open overhead clearance above the pagoda top.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eHow is the Raypak Digital winterized in Canadian climates?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eShut off the main gas cock and power breaker. Remove the header drain plugs on both the in\/out and return headers, disconnect the plumbing unions, and blow all residual moisture out with an air compressor.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/6000.18.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct brochure — Raypak pool and spa heaters (6000.18) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/241236.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and operation manual — Raypak atmospheric pool heater models 206A–406A (241236) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/9100.56.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIllustrated parts list — Raypak models 206A–406A (9100.56) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications compiled from Raypak Atmospheric Gas-Fired Pool and Spa Heater Installation and Operation Manual (P\/N 241236). All performance values and dimensions are subject to verification against official manufacturer documentation. \u003ca href=\"https:\/\/s3.amazonaws.com\/AWSProd\/sites\/raypakcom\/documents\/241236.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView the Raypak 206A–406A installation manual (PDF)\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"206A (199,500 BTU\/h) \/ Natural gas","offer_id":53973657714982,"sku":"014938","price":3089.0,"currency_code":"CAD","in_stock":true},{"title":"206A (199,500 BTU\/h) \/ Propane","offer_id":53973657747750,"sku":"014939","price":3180.0,"currency_code":"CAD","in_stock":true},{"title":"266A (266,000 BTU\/h) \/ Natural gas","offer_id":53973657780518,"sku":"014940","price":3480.0,"currency_code":"CAD","in_stock":true},{"title":"266A (266,000 BTU\/h) \/ Propane","offer_id":53973657813286,"sku":"014941","price":3680.0,"currency_code":"CAD","in_stock":true},{"title":"336A (332,500 BTU\/h) \/ Natural gas","offer_id":53973657846054,"sku":"014942","price":4180.0,"currency_code":"CAD","in_stock":true},{"title":"336A (332,500 BTU\/h) \/ Propane","offer_id":53973657878822,"sku":"014943","price":4180.0,"currency_code":"CAD","in_stock":true},{"title":"406A (399,000 BTU\/h) \/ Natural gas","offer_id":53973657911590,"sku":"014944","price":4380.0,"currency_code":"CAD","in_stock":true},{"title":"406A (399,000 BTU\/h) \/ Propane","offer_id":53973657944358,"sku":"014945","price":4980.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/raypak-digital-gas-pool-heater_db8abba7-efcc-46d4-906e-49f975ab9fa8.jpg?v=1790688852"},{"product_id":"pentair-sta-rite-max-e-therm-gas-pool-heater","title":"Pentair Sta-Rite Max-E-Therm High-Performance Gas Pool Heater","description":"\u003cp\u003e\u003cstrong\u003eA compact, high-efficiency gas pool and spa heater featuring a rustproof Dura-Glas composite housing and intuitive digital controls.\u003c\/strong\u003e Engineered by Pentair, the Sta-Rite Max-E-Therm series combines fast heat-up performance with rugged weatherproof construction built to handle demanding Canadian outdoor environments. Available in 200,000, 333,000, and 400,000 BTU\/h capacities for natural gas or propane installations, the Max-E-Therm delivers 84% thermal efficiency, a premix combustion blower system, and hot-surface ignition.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRustproof Dura-Glas composite housing\u003c\/strong\u003e — sleek, rounded composite exterior eliminates metal corrosion, peeling paint, and rust stains on the pool equipment pad.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremix combustion with induced draft blower\u003c\/strong\u003e — completely enclosed air\/gas mixing system provides stable flame control and clean combustion even under variable outdoor wind conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-surface ignition (HSI)\u003c\/strong\u003e — direct electronic silicon carbide igniter eliminates standing pilot lights, reducing standby fuel consumption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision digital dual-temperature display\u003c\/strong\u003e — top-mounted rotatable control panel features dual digital thermostats for seamless pool and spa temperature switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart automation ready\u003c\/strong\u003e — integrates directly with Pentair IntelliCenter, IntelliTouch, and EasyTouch automation systems via standard two-wire communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect-vent indoor capability\u003c\/strong\u003e — certified for outdoor installation as well as indoor mechanical room ventilation using certified Category III or IV stainless venting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSizing guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRated input\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eTypical pool surface area\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eTypical pool volume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eApplication\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSR200\u003c\/th\u003e\n\u003ctd\u003e200,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eUp to 450 sq ft\u003c\/td\u003e\n\u003ctd\u003eUp to 55,000 L (14,500 US gal)\u003c\/td\u003e\n\u003ctd\u003eStandalone spas and smaller in-ground pools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSR333\u003c\/th\u003e\n\u003ctd\u003e333,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eUp to 750 sq ft\u003c\/td\u003e\n\u003ctd\u003eUp to 95,000 L (25,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eMid-size in-ground pools and rapid spa heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSR400\u003c\/th\u003e\n\u003ctd\u003e400,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 sq ft\u003c\/td\u003e\n\u003ctd\u003eUp to 130,000 L (34,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eLarge residential pools and extended shoulder seasons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ch3\u003ePerformance\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSR200NA \/ LP\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSR333NA \/ LP\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSR400NA \/ LP\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInput capacity\u003c\/th\u003e\n\u003ctd\u003e200,000 BTU\/h (58.6 kW)\u003c\/td\u003e\n\u003ctd\u003e333,000 BTU\/h (97.6 kW)\u003c\/td\u003e\n\u003ctd\u003e400,000 BTU\/h (117.2 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eThermal efficiency\u003c\/th\u003e\n\u003ctd\u003e84.0%\u003c\/td\u003e\n\u003ctd\u003e84.0%\u003c\/td\u003e\n\u003ctd\u003e84.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition type\u003c\/th\u003e\n\u003ctd\u003eDirect hot-surface ignition (HSI)\u003c\/td\u003e\n\u003ctd\u003eDirect hot-surface ignition (HSI)\u003c\/td\u003e\n\u003ctd\u003eDirect hot-surface ignition (HSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBlower system\u003c\/th\u003e\n\u003ctd\u003eInduced draft combustion blower\u003c\/td\u003e\n\u003ctd\u003eInduced draft combustion blower\u003c\/td\u003e\n\u003ctd\u003eInduced draft combustion blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eFin-tube copper with bronze headers\u003c\/td\u003e\n\u003ctd\u003eFin-tube copper with bronze headers\u003c\/td\u003e\n\u003ctd\u003eFin-tube copper with bronze headers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEmissions profile\u003c\/th\u003e\n\u003ctd\u003eLow-NOx certified (\u0026lt;40 ng\/J)\u003c\/td\u003e\n\u003ctd\u003eLow-NOx certified (\u0026lt;40 ng\/J)\u003c\/td\u003e\n\u003ctd\u003eLow-NOx certified (\u0026lt;40 ng\/J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHydraulic \u0026amp; plumbing\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePlumbing connection size\u003c\/th\u003e\n\u003ctd\u003e2 in. CPVC slip unions included (reversible header for left or right piping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum water flow rate\u003c\/th\u003e\n\u003ctd\u003e40 US gpm (151 L\/min) across all sizes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum water flow rate\u003c\/th\u003e\n\u003ctd\u003e120 US gpm (454 L\/min); external manual bypass required above 120 gpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInternal bypass valve\u003c\/th\u003e\n\u003ctd\u003eAutomatic built-in thermal regulating bypass valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum working pressure\u003c\/th\u003e\n\u003ctd\u003e50 psi (345 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFuel supply \u0026amp; electrical\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eNatural gas models (NA)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePropane models (LP)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel inlet connection\u003c\/th\u003e\n\u003ctd\u003e3\/4 in. NPT female\u003c\/td\u003e\n\u003ctd\u003e3\/4 in. NPT female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas supply pressure (inlet min \/ max)\u003c\/th\u003e\n\u003ctd\u003e4.0 in. w.c. \/ 14.0 in. w.c.\u003c\/td\u003e\n\u003ctd\u003e10.0 in. w.c. \/ 14.0 in. w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManifold operating pressure\u003c\/th\u003e\n\u003ctd\u003eNormal: 3.5 in. w.c.\u003c\/td\u003e\n\u003ctd\u003eNormal: 10.0 in. w.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical supply\u003c\/th\u003e\n\u003ctd\u003e115 V AC or 230 V AC, 60 Hz, single phase (convertible field plug)\u003c\/td\u003e\n\u003ctd\u003e115 V AC or 230 V AC, 60 Hz, single phase (convertible field plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating current\u003c\/th\u003e\n\u003ctd\u003e5.5 A at 115 V AC \/ 3.0 A at 230 V AC\u003c\/td\u003e\n\u003ctd\u003e5.5 A at 115 V AC \/ 3.0 A at 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCabinet dimensions \u0026amp; weight\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eDimension\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSR200\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSR333\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSR400\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e30.18 in. (767 mm)\u003c\/td\u003e\n\u003ctd\u003e30.18 in. (767 mm)\u003c\/td\u003e\n\u003ctd\u003e30.18 in. (767 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWidth (cabinet diameter)\u003c\/th\u003e\n\u003ctd\u003e28.14 in. (715 mm)\u003c\/td\u003e\n\u003ctd\u003e28.14 in. (715 mm)\u003c\/td\u003e\n\u003ctd\u003e28.14 in. (715 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDepth (front to back)\u003c\/th\u003e\n\u003ctd\u003e33.00 in. (838 mm)\u003c\/td\u003e\n\u003ctd\u003e33.00 in. (838 mm)\u003c\/td\u003e\n\u003ctd\u003e33.00 in. (838 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e128 lb (58.1 kg)\u003c\/td\u003e\n\u003ctd\u003e138 lb (62.6 kg)\u003c\/td\u003e\n\u003ctd\u003e149 lb (67.6 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas lines, meter regulators, and venting must be sized and installed in compliance with CSA B149.1 (Natural Gas and Propane Installation Code) and local utility standards by a licensed gas technician.\u003c\/li\u003e\n\u003cli\u003eElectrical connections require a dedicated 15 A 120 V or 240 V branch circuit compliant with the Canadian Electrical Code (CSA C22.1). Ensure proper bonding to the pool bonding grid with a minimum 6 AWG copper conductor.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum clearances from combustible construction: 6 in. on top, 6 in. on rear, 6 in. on right side, and 12 in. on water connection side. Provide 36 in. front clearance for maintenance access.\u003c\/li\u003e\n\u003cli\u003eMaintain balanced water chemistry (pH 7.4–7.6, total alkalinity 80–120 ppm, calcium hardness 200–400 ppm) to ensure long heat exchanger operating life.\u003c\/li\u003e\n\u003cli\u003eFor winter freeze protection in cold climates, drain all water by opening the manifold drain plug and clearing connecting piping with compressed air.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHave questions about gas line sizing or selecting between 200K, 333K, or 400K BTU\/h? Request a product quote or see the manufacturer documents below.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eDoes the Max-E-Therm feature a reversible water header?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The plumbing connections can be reversed from the factory right-hand side to left-hand side in the field to match existing equipment pad pipe runs.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat is the natural gas supply pressure requirement?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eSupply gas pressure must measure between 4.0 inches W.C. minimum and 14.0 inches W.C. maximum during firing load. A licensed gas technician must verify line sizing under CSA B149.1.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eIs the Max-E-Therm certified as Low-NOx?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The unit produces low nitrogen oxide emissions under 40 ng\/J, meeting all Canadian environmental air quality standards.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan the Max-E-Therm connect to automated pool controllers?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The heater supports two-wire connection to Pentair IntelliCenter, EasyTouch, and compatible digital pool automation systems.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat clearance is needed around the circular housing?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eAllow 6 inches (150 mm) of clearance on non-plumbing sides, 12 inches (300 mm) on the plumbing side, 18 inches (450 mm) for control panel access, and unrestricted overhead clearance.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eHow do I winterize the Max-E-Therm for sub-zero temperatures?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eTurn off electrical power and shut off the gas supply. Remove the water header drain plug, disconnect the PVC union couplings, blow out any standing water inside the exchanger with low-pressure air, and fit a protective cover.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/max-e-therm\/brochure\/max-e-therm-heaters-for-pools-and-spas-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification brochure — Sta-Rite Max-E-Therm (English) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/max-e-therm\/manuals\/max-e-therm-manual-english.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation and user's guide — Sta-Rite Max-E-Therm (English) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/max-e-therm\/manuals\/Max-E-Therm_Pool_and_Spa_Heater_Users_Guide_French.pdf\" target=\"_blank\" rel=\"noopener\"\u003eGuide d'installation et d'utilisation — Sta-Rite Max-E-Therm (French) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/max-e-therm\/manuals\/starite-maxetherm-heater-submittal-data-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEngineering submittal data sheet — Sta-Rite Max-E-Therm (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications sourced from Pentair Sta-Rite Max-E-Therm Installation and User's Guide (P\/N 473435 Rev D), brochure (P\/N STA-MAXBR-EN), and engineering submittal data. Specifications are subject to change by the manufacturer. \u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/max-e-therm\/manuals\/max-e-therm-manual-english.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView the Pentair Sta-Rite Max-E-Therm manual (PDF)\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"200K BTU\/h \/ Natural gas","offer_id":53973699690790,"sku":"SR200NA","price":4150.0,"currency_code":"CAD","in_stock":true},{"title":"200K BTU\/h \/ Propane","offer_id":53973699723558,"sku":"SR200LP","price":4150.0,"currency_code":"CAD","in_stock":true},{"title":"333K BTU\/h \/ Natural gas","offer_id":53973699756326,"sku":"SR333NA","price":4650.0,"currency_code":"CAD","in_stock":true},{"title":"333K BTU\/h \/ Propane","offer_id":53973699789094,"sku":"SR333LP","price":4650.0,"currency_code":"CAD","in_stock":true},{"title":"400K BTU\/h \/ Natural gas","offer_id":53973699821862,"sku":"SR400NA","price":5150.0,"currency_code":"CAD","in_stock":true},{"title":"400K BTU\/h \/ Propane","offer_id":53973699854630,"sku":"SR400LP","price":5150.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/pentair-sta-rite-max-e-therm-gas-pool-heater.png?v=1790689747"}],"url":"https:\/\/avlshop.ca\/collections\/gas-pool-heaters.oembed","provider":"AVL Shop","version":"1.0","type":"link"}