{"title":"Heat Pump Pool Heaters","description":null,"products":[{"product_id":"hayward-heatpro-vs-inverter-pool-heat-pump","title":"Hayward HeatPro VS Inverter Pool Heat Pump","description":"\u003cp\u003e\u003cstrong\u003eVariable-speed inverter pool heat pump with titanium counter-flow heat exchanger for quiet, continuous swimming season extension.\u003c\/strong\u003e Engineered specifically for Canadian climates, the Hayward HeatPro VS series modulates heating output between 20% and 100% capacity to maintain precise pool water temperatures with up to 50% energy savings over standard single-speed units. Available in 80,000 BTU\/h side-discharge (HP80CLEE1) and 115,000 to 140,000 BTU\/h vertical top-discharge (HP115CLEE1 \/ HP140CLEE1) platforms for residential in-ground and on-ground pools up to 130,000 L (34,000 US gal).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-speed inverter rotary compressor\u003c\/strong\u003e — automatically modulates compressor and fan speeds to match real-time heat loss, maintaining target water temperature with sound levels as low as 40–54 dB(A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCounter-flow titanium heat exchanger\u003c\/strong\u003e — impervious to corrosion from electrolytic saltwater chlorinators (3,000+ ppm NaCl) and aggressive pool water chemistry balance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive hot-gas defrost system\u003c\/strong\u003e — integrated reversing valve de-ices evaporator coils automatically, enabling dependable heating during chilly Ontario spring and autumn shoulder seasons down to 4 °C (40 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated soft-start electronics\u003c\/strong\u003e — ramps motor speed smoothly from 0 rpm, eliminating high inrush current spikes and ensuring electrical service stability on residential panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital keypad and automation compatibility\u003c\/strong\u003e — weather-protected digital touchscreen interface with built-in diagnostic codes, compatible with Hayward OmniLogic automation and standard 2-wire remote controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual architectural chassis platforms\u003c\/strong\u003e — compact horizontal side-discharge cabinet (HP80CLEE1) for tight pad spaces and wall clearances, alongside high-capacity vertical top-discharge cabinets (HP115CLEE1 \/ HP140CLEE1) with wrapped blue-fin coil arrays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSizing guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRated thermal output (80\/80\/80)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCool ambient output (50\/80\/63)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRecommended pool volume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eChassis architecture\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHP80CLEE1\u003c\/th\u003e\n\u003ctd\u003e79,000 BTU\/h (23.1 kW)\u003c\/td\u003e\n\u003ctd\u003e50,000 BTU\/h (14.6 kW)\u003c\/td\u003e\n\u003ctd\u003eUp to 55,000 L (14,500 US gal)\u003c\/td\u003e\n\u003ctd\u003eHorizontal side-discharge (front fan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHP115CLEE1\u003c\/th\u003e\n\u003ctd\u003e115,000 BTU\/h (33.7 kW)\u003c\/td\u003e\n\u003ctd\u003e56,300 BTU\/h (16.5 kW)\u003c\/td\u003e\n\u003ctd\u003eUp to 80,000 L (21,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eVertical top-discharge (architectural cubic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHP140CLEE1\u003c\/th\u003e\n\u003ctd\u003e140,000 BTU\/h (41.0 kW)\u003c\/td\u003e\n\u003ctd\u003e63,000 BTU\/h (18.5 kW)\u003c\/td\u003e\n\u003ctd\u003eUp to 130,000 L (34,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eVertical top-discharge (high-capacity cubic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eHP80CLEE1\u003c\/th\u003e\n\u003cth\u003eHP115CLEE1\u003c\/th\u003e\n\u003cth\u003eHP140CLEE1\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ SKU\u003c\/td\u003e\n\u003ctd\u003eHP80CLEE1\u003c\/td\u003e\n\u003ctd\u003eHP115CLEE1\u003c\/td\u003e\n\u003ctd\u003eHP140CLEE1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eThermal Performance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated heating capacity (80 °F air, 80 °F water, 80% RH)\u003c\/td\u003e\n\u003ctd\u003e79,000 BTU\/h (23.1 kW)\u003c\/td\u003e\n\u003ctd\u003e115,000 BTU\/h (33.7 kW)\u003c\/td\u003e\n\u003ctd\u003e140,000 BTU\/h (41.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCool ambient capacity (50 °F air, 80 °F water, 63% RH)\u003c\/td\u003e\n\u003ctd\u003e50,000 BTU\/h (14.6 kW)\u003c\/td\u003e\n\u003ctd\u003e56,300 BTU\/h (16.5 kW)\u003c\/td\u003e\n\u003ctd\u003e63,000 BTU\/h (18.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoefficient of performance (COP, 80\/80\/80)\u003c\/td\u003e\n\u003ctd\u003e5.3\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoefficient of performance (COP, 50\/80\/63)\u003c\/td\u003e\n\u003ctd\u003e4.1\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003ctd\u003e4.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor technology\u003c\/td\u003e\n\u003ctd\u003eDC Inverter Rotary\u003c\/td\u003e\n\u003ctd\u003eDC Inverter Rotary\u003c\/td\u003e\n\u003ctd\u003eDC Inverter Rotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exchanger metallurgy\u003c\/td\u003e\n\u003ctd\u003eCounter-flow pure titanium tube\u003c\/td\u003e\n\u003ctd\u003eCounter-flow pure titanium tube\u003c\/td\u003e\n\u003ctd\u003eCounter-flow pure titanium tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSaltwater chlorination compatibility\u003c\/td\u003e\n\u003ctd\u003eCompatible with all residential salt chlorine systems\u003c\/td\u003e\n\u003ctd\u003eCompatible with all residential salt chlorine systems\u003c\/td\u003e\n\u003ctd\u003eCompatible with all residential salt chlorine systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefrost technology\u003c\/td\u003e\n\u003ctd\u003eActive hot-gas reversing valve\u003c\/td\u003e\n\u003ctd\u003eActive hot-gas reversing valve\u003c\/td\u003e\n\u003ctd\u003eActive hot-gas reversing valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eElectrical \u0026amp; Power Requirements\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical supply\u003c\/td\u003e\n\u003ctd\u003e208–230 V, 1-phase, 60 Hz\u003c\/td\u003e\n\u003ctd\u003e208–230 V, 1-phase, 60 Hz\u003c\/td\u003e\n\u003ctd\u003e208–230 V, 1-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum circuit ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003ctd\u003e45 A\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum overcurrent protection (MOP \/ Breaker)\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power input (kW at 80\/80\/80)\u003c\/td\u003e\n\u003ctd\u003e0.92–4.34 kW\u003c\/td\u003e\n\u003ctd\u003e1.14–6.74 kW\u003c\/td\u003e\n\u003ctd\u003e1.74–8.20 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating sound level\u003c\/td\u003e\n\u003ctd\u003e40–54 dB(A)\u003c\/td\u003e\n\u003ctd\u003e50–58 dB(A)\u003c\/td\u003e\n\u003ctd\u003e50–58 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eWater Hydraulics\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater flow rate (minimum \/ maximum)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 189 L\/min (18 \/ 50 GPM)\u003c\/td\u003e\n\u003ctd\u003e92 \/ 266 L\/min (24.2 \/ 70.4 GPM)\u003c\/td\u003e\n\u003ctd\u003e117 \/ 333 L\/min (30.8 \/ 88.0 GPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlumbing union connection\u003c\/td\u003e\n\u003ctd\u003e2 in. \/ 2.5 in. CPVC unions included\u003c\/td\u003e\n\u003ctd\u003e2 in. \/ 2.5 in. CPVC unions included\u003c\/td\u003e\n\u003ctd\u003e2 in. \/ 2.5 in. CPVC unions included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant charge\u003c\/td\u003e\n\u003ctd\u003eR-410A\u003c\/td\u003e\n\u003ctd\u003eR-410A\u003c\/td\u003e\n\u003ctd\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eDimensions \u0026amp; Weight\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet architecture\u003c\/td\u003e\n\u003ctd\u003eHorizontal side-discharge\u003c\/td\u003e\n\u003ctd\u003eVertical top-discharge\u003c\/td\u003e\n\u003ctd\u003eVertical top-discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e116.1 × 49.0 × 86.1 cm (45.7 × 19.3 × 33.9 in)\u003c\/td\u003e\n\u003ctd\u003e83.3 × 81.3 × 106.4 cm (32.8 × 32.0 × 41.9 in)\u003c\/td\u003e\n\u003ctd\u003e83.3 × 81.3 × 106.4 cm (32.8 × 32.0 × 41.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet equipment weight\u003c\/td\u003e\n\u003ctd\u003e87 kg (191.8 lb)\u003c\/td\u003e\n\u003ctd\u003e109 kg (240.0 lb)\u003c\/td\u003e\n\u003ctd\u003e124 kg (273.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e90 kg (198.4 lb)\u003c\/td\u003e\n\u003ctd\u003e116 kg (255.7 lb)\u003c\/td\u003e\n\u003ctd\u003e131 kg (288.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical supply requires a dedicated 208–230 V single-phase 60 Hz circuit with an outdoor weatherproof disconnect switch (50 A breaker \/ 32 A MCA for HP80; 70 A breaker \/ 45–50 A MCA for HP115\/HP140), bonded to the pool grid per Canadian Electrical Code (CSA C22.1).\u003c\/li\u003e\n\u003cli\u003eConfirm your pool pump provides the minimum required water flow rate (18 GPM for HP80, 24.2 GPM for HP115, 30.8 GPM for HP140). An external bypass loop is recommended on high-flow variable-speed systems exceeding maximum GPM ratings.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate outdoor clearance: horizontal side-discharge units (HP80CLEE1) require 1.5 m (5 ft) front exhaust clearance; vertical top-discharge units (HP115CLEE1 \/ HP140CLEE1) require 30 cm (12 in.) perimeter coil clearance and unrestricted upward overhead exhaust.\u003c\/li\u003e\n\u003cli\u003eMaintain balanced water chemistry (pH 7.2–7.8, total alkalinity 80–120 ppm, calcium hardness 200–400 ppm, and salt concentration 2,700–3,400 ppm) to ensure optimal operating efficiency and equipment longevity.\u003c\/li\u003e\n\u003cli\u003eFor Canadian winter shutdown, disconnect CPVC plumbing unions, open manifold drain plugs, and blow clear all internal water passages with compressed air before freezing temperatures arrive.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed assistance confirming pool volume sizing, electrical panel capacity, or plumbing pad clearance? Request a quote and our equipment team will verify the optimal configuration and availability for your pool.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat plumbing connections are provided with the unit?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe unit includes factory 2-inch by 2.5-inch CPVC plumbing union connectors that solvent-weld directly to standard rigid Schedule 40 PVC pool piping.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan this unit be controlled through pool automation systems?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The built-in digital keypad supports 2-wire remote connection and low-voltage RS-485 communication compatible with Hayward OmniLogic, OmniHub, and third-party relay automation panels.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat equipment pad clearances are required?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe horizontal side-discharge model (HP80CLEE1) requires 1.5 m (5 ft) of open discharge clearance in front of the fan and 30 cm (12 in.) around intake louvers. Vertical models (HP115\/140) require 30 cm perimeter coil clearance and unrestricted upward overhead exhaust clearance.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eHow do I winterize the Hayward HeatPro VS in Canada?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003ePrior to winter freeze conditions, turn off electrical power at the breaker, unscrew both CPVC plumbing unions, remove the drain plugs at the bottom of the heat exchanger manifold, blow out internal water channels with oil-free compressed air, and fit a breathable protective cover over the cabinet.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/a.storyblok.com\/f\/97589\/x\/f5217e7e51\/heatpro-vs-family-brochure.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHayward HeatPro VS Variable-Speed Inverter Pool Heat Pump Specification Brochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications derived from Hayward Canada Variable-Speed Heat Pump Specification Sheet (Lit. LITHPCL25C) and HeatPro VS Installation \u0026amp; Operation Manual. Specifications are subject to change by the manufacturer. \u003ca href=\"https:\/\/a.storyblok.com\/f\/97589\/x\/f5217e7e51\/heatpro-vs-family-brochure.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView the Hayward brochure (PDF)\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; Safety Notice:\u003c\/strong\u003e Swimming pool heat pumps require dedicated 240V electrical service and adequate outdoor airflow clearances. Installation must be completed by a licensed refrigeration\/HVAC technician and certified electrician.\u003c\/p\u003e","brand":"Hayward","offers":[{"title":"80,000 BTU\/h (HP80CLEE1)","offer_id":53973661548838,"sku":"HP80CLEE1","price":3289.0,"currency_code":"CAD","in_stock":true},{"title":"115,000 BTU\/h (HP115CLEE1)","offer_id":53973661581606,"sku":"HP115CLEE1","price":4689.0,"currency_code":"CAD","in_stock":true},{"title":"140,000 BTU\/h (HP140CLEE1)","offer_id":53973661647142,"sku":"HP140CLEE1","price":5899.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/hayward-heatpro-vs-inverter-pool-heat-pump-lineup_2de56ab6-1544-4b42-a09c-62a6079f56f9.jpg?v=1790715679"},{"product_id":"moov-inverter-pool-heat-pump","title":"Moov Inverter Variable-Speed Pool Heat Pump","description":"\u003cp\u003e\u003cstrong\u003eA full-inverter variable-speed swimming pool heat pump engineered with twin-rotary DC compression and spiral titanium heat exchange for ultra-quiet seasonal heating.\u003c\/strong\u003e The Moov Inverter series continuously regulates compressor and fan speed between 20% and 100% capacity to maintain steady water temperatures while cutting energy draw compared to traditional on\/off heaters. Featuring soft-starter power electronics, side or top air discharge configurations, and high part-load efficiency, Moov provides reliable, whisper-quiet heating across Canada's swimming season.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-inverter modulation\u003c\/strong\u003e — intelligent DC inverter driver adjusts motor and compressor output dynamically between 20% and 100% capacity, matching real-time pool heat loss with optimal power usage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh average COP performance\u003c\/strong\u003e — delivers a seasonal coefficient of performance (COP) up to 8.0, reducing annual electricity consumption compared to fixed-speed heat pumps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpiral twisted titanium heat exchanger\u003c\/strong\u003e — corrugated spiral titanium tube expands surface area by 30% for rapid heat transfer and total immunity against chlorine and salt corrosion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft-start current protection\u003c\/strong\u003e — starts from 0 A and ramps smoothly to operating current, eliminating electrical surges and voltage drops on residential panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhisper-quiet acoustic design\u003c\/strong\u003e — sound-dampened inverter compressor and variable-speed fan blades achieve sound levels as low as 48 dB(A) at 1 m in low-speed maintenance mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLockable digital touch control\u003c\/strong\u003e — front-mounted digital display provides precise temperature selection with screen lock functionality and diagnostic status monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eMoov Pool Products\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eMoov Full-Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEquipment type\u003c\/th\u003e\n\u003ctd\u003eVariable-speed air-source pool heat pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable models\u003c\/th\u003e\n\u003ctd\u003eMI500 (50K) \/ MI650 (66K) \/ MI900 (90K) \/ MI1100 (110K) \/ MI1400 (140K) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pool volume (MI500)\u003c\/th\u003e\n\u003ctd\u003eUp to 52,000 L (14,000 US gal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pool volume (MI650)\u003c\/th\u003e\n\u003ctd\u003eUp to 68,000 L (18,000 US gal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pool volume (MI900)\u003c\/th\u003e\n\u003ctd\u003eUp to 105,000 L (28,000 US gal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pool volume (MI1100)\u003c\/th\u003e\n\u003ctd\u003eUp to 120,000 L (32,000 US gal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pool volume (MI1400)\u003c\/th\u003e\n\u003ctd\u003eUp to 160,000 L (42,000 US gal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCoefficient of performance (COP)\u003c\/th\u003e\n\u003ctd\u003eUp to 8.0 (at 27 °C air \/ 26 °C water \/ 80% humidity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompressor technology\u003c\/th\u003e\n\u003ctd\u003eDC Twin-Rotary variable-speed inverter compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eSpiral twisted pure titanium tube in rigid PVC shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir discharge type (MI500–MI900)\u003c\/th\u003e\n\u003ctd\u003eHorizontal side-discharge fan with protective front grille\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir discharge type (MI1100–MI1400)\u003c\/th\u003e\n\u003ctd\u003eVertical top-discharge fan with top safety grille\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating air temperature range\u003c\/th\u003e\n\u003ctd\u003e0 °C to 43 °C (32 °F to 110 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSound level (low speed)\u003c\/th\u003e\n\u003ctd\u003e48 to 52 dB(A) at 1 m depending on capacity tier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePlumbing connections\u003c\/th\u003e\n\u003ctd\u003e1-1\/2 in. \/ 2 in. quick-connect PVC unions included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended water flow (MI500–MI900)\u003c\/th\u003e\n\u003ctd\u003e20 to 50 GPM (76 to 189 L\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended water flow (MI1100–MI1400)\u003c\/th\u003e\n\u003ctd\u003e35 to 70 GPM (132 to 265 L\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e208\/240 V AC, single phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCasing construction\u003c\/th\u003e\n\u003ctd\u003eWeatherproof aluminum alloy and structural ABS composite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondensate management\u003c\/th\u003e\n\u003ctd\u003eIntegrated base drain pan with attachable drain nozzle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003ecETLus certified to CSA C22.2 and UL standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated 240 V electrical service with an external disconnect switch must be installed by a licensed electrician according to the Canadian Electrical Code (CSA C22.1).\u003c\/li\u003e\n\u003cli\u003eSide-discharge models (MI500, MI650, MI900) require at least 50 cm (20 in.) clearance on intake faces and 150 cm (59 in.) in front of the fan exhaust.\u003c\/li\u003e\n\u003cli\u003eTop-discharge models (MI1100, MI1400) require at least 244 cm (8 ft) of unobstructed overhead clearance above the fan discharge.\u003c\/li\u003e\n\u003cli\u003eInstall the heat pump outdoors on a level concrete pad or composite equipment base with clear drainage for natural condensation.\u003c\/li\u003e\n\u003cli\u003eBefore freezing temperatures occur in late autumn, disconnect plumbing unions and drain all residual water completely from the heat exchanger canister to prevent freeze damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHave questions about electrical service capacity or volume matching? Contact our technical support team for assistance.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat size plumbing pipes does the heat exchanger accept?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe unit includes standard 1.5-inch or 2-inch quick-connect plumbing unions for solvent cementing into standard Schedule 40 PVC pool return lines.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan the unit also cool pool water during mid-summer heatwaves?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The reversible refrigeration circuit provides both heating and cooling modes, allowing owners to cool warm pool water down to comfortable swimming temperatures during extreme summer heat.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eHow should the unit be prepped for Canadian winter temperatures?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eTurn off the electrical breaker, loosen the inlet and outlet union collars, remove the drain valve plug to empty the titanium drum, blow dry with air, and wrap with a winter weather cover.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/moovpool.com\/wp-content\/uploads\/2023\/09\/instruction-manual-for-moov-inverter-enfr.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstruction and operation manual — Moov Inverter pool heat pump (English and French) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/moovpool.com\/wp-content\/uploads\/2023\/02\/moov-inverter-en-2023-pdf.pdf\" target=\"_blank\" rel=\"noopener\"\u003eTechnical brochure and specifications — Moov Inverter series (2023) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/moovpool.com\/wp-content\/uploads\/2021\/04\/moov-inverter-brochure-en.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct brochure — Moov Inverter heat pump (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications compiled from Moov Full-Inverter Heat Pump Instruction Manual (EN\/FR) and Moov Inverter 2023 Technical Brochure. All performance ratings subject to verification by manufacturer engineering documentation. \u003ca href=\"https:\/\/moovpool.com\/wp-content\/uploads\/2023\/09\/instruction-manual-for-moov-inverter-enfr.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView the Moov Inverter manual (PDF)\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e","brand":"Moov","offers":[{"title":"MI500 (50,000 BTU\/h)","offer_id":53973661679910,"sku":"MI500","price":2180.0,"currency_code":"CAD","in_stock":true},{"title":"MI650 (66,000 BTU\/h)","offer_id":53973661712678,"sku":"MI650","price":2780.0,"currency_code":"CAD","in_stock":true},{"title":"MI900 (90,000 BTU\/h)","offer_id":53973661745446,"sku":"MI900","price":3999.0,"currency_code":"CAD","in_stock":true},{"title":"MI1100 (110,000 BTU\/h)","offer_id":53973661778214,"sku":"MI1100","price":4980.0,"currency_code":"CAD","in_stock":true},{"title":"MI1400 (140,000 BTU\/h)","offer_id":53973661810982,"sku":"MI1400","price":6299.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/moov-inverter-pool-heat-pump.png?v=1790688908"}],"url":"https:\/\/avlshop.ca\/collections\/heat-pump-pool-heaters.oembed","provider":"AVL Shop","version":"1.0","type":"link"}