{"product_id":"hayward-heatpro-vs-inverter-pool-heat-pump","title":"Hayward HeatPro VS Inverter Pool Heat Pump","description":"\u003cp\u003e\u003cstrong\u003eVariable-speed inverter pool heat pump with titanium counter-flow heat exchanger for quiet, continuous swimming season extension.\u003c\/strong\u003e Engineered specifically for Canadian climates, the Hayward HeatPro VS series modulates heating output between 20% and 100% capacity to maintain precise pool water temperatures with up to 50% energy savings over standard single-speed units. Available in 80,000 BTU\/h side-discharge (HP80CLEE1) and 115,000 to 140,000 BTU\/h vertical top-discharge (HP115CLEE1 \/ HP140CLEE1) platforms for residential in-ground and on-ground pools up to 130,000 L (34,000 US gal).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariable-speed inverter rotary compressor\u003c\/strong\u003e — automatically modulates compressor and fan speeds to match real-time heat loss, maintaining target water temperature with sound levels as low as 40–54 dB(A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCounter-flow titanium heat exchanger\u003c\/strong\u003e — impervious to corrosion from electrolytic saltwater chlorinators (3,000+ ppm NaCl) and aggressive pool water chemistry balance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive hot-gas defrost system\u003c\/strong\u003e — integrated reversing valve de-ices evaporator coils automatically, enabling dependable heating during chilly Ontario spring and autumn shoulder seasons down to 4 °C (40 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated soft-start electronics\u003c\/strong\u003e — ramps motor speed smoothly from 0 rpm, eliminating high inrush current spikes and ensuring electrical service stability on residential panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital keypad and automation compatibility\u003c\/strong\u003e — weather-protected digital touchscreen interface with built-in diagnostic codes, compatible with Hayward OmniLogic automation and standard 2-wire remote controls.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual architectural chassis platforms\u003c\/strong\u003e — compact horizontal side-discharge cabinet (HP80CLEE1) for tight pad spaces and wall clearances, alongside high-capacity vertical top-discharge cabinets (HP115CLEE1 \/ HP140CLEE1) with wrapped blue-fin coil arrays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSizing guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRated thermal output (80\/80\/80)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCool ambient output (50\/80\/63)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRecommended pool volume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eChassis architecture\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHP80CLEE1\u003c\/th\u003e\n\u003ctd\u003e79,000 BTU\/h (23.1 kW)\u003c\/td\u003e\n\u003ctd\u003e50,000 BTU\/h (14.6 kW)\u003c\/td\u003e\n\u003ctd\u003eUp to 55,000 L (14,500 US gal)\u003c\/td\u003e\n\u003ctd\u003eHorizontal side-discharge (front fan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHP115CLEE1\u003c\/th\u003e\n\u003ctd\u003e115,000 BTU\/h (33.7 kW)\u003c\/td\u003e\n\u003ctd\u003e56,300 BTU\/h (16.5 kW)\u003c\/td\u003e\n\u003ctd\u003eUp to 80,000 L (21,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eVertical top-discharge (architectural cubic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHP140CLEE1\u003c\/th\u003e\n\u003ctd\u003e140,000 BTU\/h (41.0 kW)\u003c\/td\u003e\n\u003ctd\u003e63,000 BTU\/h (18.5 kW)\u003c\/td\u003e\n\u003ctd\u003eUp to 130,000 L (34,000 US gal)\u003c\/td\u003e\n\u003ctd\u003eVertical top-discharge (high-capacity cubic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eHP80CLEE1\u003c\/th\u003e\n\u003cth\u003eHP115CLEE1\u003c\/th\u003e\n\u003cth\u003eHP140CLEE1\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ SKU\u003c\/td\u003e\n\u003ctd\u003eHP80CLEE1\u003c\/td\u003e\n\u003ctd\u003eHP115CLEE1\u003c\/td\u003e\n\u003ctd\u003eHP140CLEE1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eThermal Performance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated heating capacity (80 °F air, 80 °F water, 80% RH)\u003c\/td\u003e\n\u003ctd\u003e79,000 BTU\/h (23.1 kW)\u003c\/td\u003e\n\u003ctd\u003e115,000 BTU\/h (33.7 kW)\u003c\/td\u003e\n\u003ctd\u003e140,000 BTU\/h (41.0 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCool ambient capacity (50 °F air, 80 °F water, 63% RH)\u003c\/td\u003e\n\u003ctd\u003e50,000 BTU\/h (14.6 kW)\u003c\/td\u003e\n\u003ctd\u003e56,300 BTU\/h (16.5 kW)\u003c\/td\u003e\n\u003ctd\u003e63,000 BTU\/h (18.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoefficient of performance (COP, 80\/80\/80)\u003c\/td\u003e\n\u003ctd\u003e5.3\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoefficient of performance (COP, 50\/80\/63)\u003c\/td\u003e\n\u003ctd\u003e4.1\u003c\/td\u003e\n\u003ctd\u003e4.0\u003c\/td\u003e\n\u003ctd\u003e4.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor technology\u003c\/td\u003e\n\u003ctd\u003eDC Inverter Rotary\u003c\/td\u003e\n\u003ctd\u003eDC Inverter Rotary\u003c\/td\u003e\n\u003ctd\u003eDC Inverter Rotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exchanger metallurgy\u003c\/td\u003e\n\u003ctd\u003eCounter-flow pure titanium tube\u003c\/td\u003e\n\u003ctd\u003eCounter-flow pure titanium tube\u003c\/td\u003e\n\u003ctd\u003eCounter-flow pure titanium tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSaltwater chlorination compatibility\u003c\/td\u003e\n\u003ctd\u003eCompatible with all residential salt chlorine systems\u003c\/td\u003e\n\u003ctd\u003eCompatible with all residential salt chlorine systems\u003c\/td\u003e\n\u003ctd\u003eCompatible with all residential salt chlorine systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefrost technology\u003c\/td\u003e\n\u003ctd\u003eActive hot-gas reversing valve\u003c\/td\u003e\n\u003ctd\u003eActive hot-gas reversing valve\u003c\/td\u003e\n\u003ctd\u003eActive hot-gas reversing valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eElectrical \u0026amp; Power Requirements\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical supply\u003c\/td\u003e\n\u003ctd\u003e208–230 V, 1-phase, 60 Hz\u003c\/td\u003e\n\u003ctd\u003e208–230 V, 1-phase, 60 Hz\u003c\/td\u003e\n\u003ctd\u003e208–230 V, 1-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum circuit ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003ctd\u003e45 A\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum overcurrent protection (MOP \/ Breaker)\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power input (kW at 80\/80\/80)\u003c\/td\u003e\n\u003ctd\u003e0.92–4.34 kW\u003c\/td\u003e\n\u003ctd\u003e1.14–6.74 kW\u003c\/td\u003e\n\u003ctd\u003e1.74–8.20 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating sound level\u003c\/td\u003e\n\u003ctd\u003e40–54 dB(A)\u003c\/td\u003e\n\u003ctd\u003e50–58 dB(A)\u003c\/td\u003e\n\u003ctd\u003e50–58 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eWater Hydraulics\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater flow rate (minimum \/ maximum)\u003c\/td\u003e\n\u003ctd\u003e68 \/ 189 L\/min (18 \/ 50 GPM)\u003c\/td\u003e\n\u003ctd\u003e92 \/ 266 L\/min (24.2 \/ 70.4 GPM)\u003c\/td\u003e\n\u003ctd\u003e117 \/ 333 L\/min (30.8 \/ 88.0 GPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlumbing union connection\u003c\/td\u003e\n\u003ctd\u003e2 in. \/ 2.5 in. CPVC unions included\u003c\/td\u003e\n\u003ctd\u003e2 in. \/ 2.5 in. CPVC unions included\u003c\/td\u003e\n\u003ctd\u003e2 in. \/ 2.5 in. CPVC unions included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant charge\u003c\/td\u003e\n\u003ctd\u003eR-410A\u003c\/td\u003e\n\u003ctd\u003eR-410A\u003c\/td\u003e\n\u003ctd\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eDimensions \u0026amp; Weight\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet architecture\u003c\/td\u003e\n\u003ctd\u003eHorizontal side-discharge\u003c\/td\u003e\n\u003ctd\u003eVertical top-discharge\u003c\/td\u003e\n\u003ctd\u003eVertical top-discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e116.1 × 49.0 × 86.1 cm (45.7 × 19.3 × 33.9 in)\u003c\/td\u003e\n\u003ctd\u003e83.3 × 81.3 × 106.4 cm (32.8 × 32.0 × 41.9 in)\u003c\/td\u003e\n\u003ctd\u003e83.3 × 81.3 × 106.4 cm (32.8 × 32.0 × 41.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet equipment weight\u003c\/td\u003e\n\u003ctd\u003e87 kg (191.8 lb)\u003c\/td\u003e\n\u003ctd\u003e109 kg (240.0 lb)\u003c\/td\u003e\n\u003ctd\u003e124 kg (273.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e90 kg (198.4 lb)\u003c\/td\u003e\n\u003ctd\u003e116 kg (255.7 lb)\u003c\/td\u003e\n\u003ctd\u003e131 kg (288.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical supply requires a dedicated 208–230 V single-phase 60 Hz circuit with an outdoor weatherproof disconnect switch (50 A breaker \/ 32 A MCA for HP80; 70 A breaker \/ 45–50 A MCA for HP115\/HP140), bonded to the pool grid per Canadian Electrical Code (CSA C22.1).\u003c\/li\u003e\n\u003cli\u003eConfirm your pool pump provides the minimum required water flow rate (18 GPM for HP80, 24.2 GPM for HP115, 30.8 GPM for HP140). An external bypass loop is recommended on high-flow variable-speed systems exceeding maximum GPM ratings.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate outdoor clearance: horizontal side-discharge units (HP80CLEE1) require 1.5 m (5 ft) front exhaust clearance; vertical top-discharge units (HP115CLEE1 \/ HP140CLEE1) require 30 cm (12 in.) perimeter coil clearance and unrestricted upward overhead exhaust.\u003c\/li\u003e\n\u003cli\u003eMaintain balanced water chemistry (pH 7.2–7.8, total alkalinity 80–120 ppm, calcium hardness 200–400 ppm, and salt concentration 2,700–3,400 ppm) to ensure optimal operating efficiency and equipment longevity.\u003c\/li\u003e\n\u003cli\u003eFor Canadian winter shutdown, disconnect CPVC plumbing unions, open manifold drain plugs, and blow clear all internal water passages with compressed air before freezing temperatures arrive.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed assistance confirming pool volume sizing, electrical panel capacity, or plumbing pad clearance? Request a quote and our equipment team will verify the optimal configuration and availability for your pool.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat plumbing connections are provided with the unit?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe unit includes factory 2-inch by 2.5-inch CPVC plumbing union connectors that solvent-weld directly to standard rigid Schedule 40 PVC pool piping.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan this unit be controlled through pool automation systems?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The built-in digital keypad supports 2-wire remote connection and low-voltage RS-485 communication compatible with Hayward OmniLogic, OmniHub, and third-party relay automation panels.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat equipment pad clearances are required?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe horizontal side-discharge model (HP80CLEE1) requires 1.5 m (5 ft) of open discharge clearance in front of the fan and 30 cm (12 in.) around intake louvers. Vertical models (HP115\/140) require 30 cm perimeter coil clearance and unrestricted upward overhead exhaust clearance.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eHow do I winterize the Hayward HeatPro VS in Canada?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003ePrior to winter freeze conditions, turn off electrical power at the breaker, unscrew both CPVC plumbing unions, remove the drain plugs at the bottom of the heat exchanger manifold, blow out internal water channels with oil-free compressed air, and fit a breathable protective cover over the cabinet.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/a.storyblok.com\/f\/97589\/x\/f5217e7e51\/heatpro-vs-family-brochure.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHayward HeatPro VS Variable-Speed Inverter Pool Heat Pump Specification Brochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications derived from Hayward Canada Variable-Speed Heat Pump Specification Sheet (Lit. LITHPCL25C) and HeatPro VS Installation \u0026amp; Operation Manual. Specifications are subject to change by the manufacturer. \u003ca href=\"https:\/\/a.storyblok.com\/f\/97589\/x\/f5217e7e51\/heatpro-vs-family-brochure.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView the Hayward brochure (PDF)\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; Safety Notice:\u003c\/strong\u003e Swimming pool heat pumps require dedicated 240V electrical service and adequate outdoor airflow clearances. Installation must be completed by a licensed refrigeration\/HVAC technician and certified electrician.\u003c\/p\u003e","brand":"Hayward","offers":[{"title":"80,000 BTU\/h (HP80CLEE1)","offer_id":53973661548838,"sku":"HP80CLEE1","price":3289.0,"currency_code":"CAD","in_stock":true},{"title":"115,000 BTU\/h (HP115CLEE1)","offer_id":53973661581606,"sku":"HP115CLEE1","price":4689.0,"currency_code":"CAD","in_stock":true},{"title":"140,000 BTU\/h (HP140CLEE1)","offer_id":53973661647142,"sku":"HP140CLEE1","price":5899.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/hayward-heatpro-vs-inverter-pool-heat-pump-lineup_2de56ab6-1544-4b42-a09c-62a6079f56f9.jpg?v=1790715679","url":"https:\/\/avlshop.ca\/products\/hayward-heatpro-vs-inverter-pool-heat-pump","provider":"AVL Shop","version":"1.0","type":"link"}