{"product_id":"mitsubishi-zuba-central-heat-pump","title":"Mitsubishi Zuba Central Ducted Heat Pump","description":"\u003cp\u003e\u003cstrong\u003eA whole-home cold-climate ducted heat pump system engineered specifically for Canadian sub-zero winters.\u003c\/strong\u003e The Mitsubishi Electric Zuba Central pairs an advanced Hyper-Heat Inverter (H2i) outdoor condensing unit (PUZ-HA series) with a high-efficiency multi-position indoor air handler (PVA-A series). Engineered to replace traditional gas furnaces or electric resistance systems, Zuba Central connects directly to existing central ductwork, delivering 100% rated heating capacity down to -15 °C (5 °F) and continuous high-efficiency thermal performance in deep winter temperatures down to -30 °C (-22 °F).\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHyper-Heat Inverter (H2i) technology\u003c\/strong\u003e: utilizes flash-injection bypass circuitry to maintain 100% rated heating capacity at -15 °C (5 °F) and continuous heat operation down to -30 °C (-22 °F) without supplemental electric backup heat strips in typical Canadian winter conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-position indoor air handler (PVA-A)\u003c\/strong\u003e: flexible cabinet configuration supports upflow, downflow, horizontal left, and horizontal right configurations, fitting existing furnace duct drop configurations with minimal sheet metal alterations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModulating inverter compressor\u003c\/strong\u003e: variable-speed inverter continuously adjusts output capacity to exact indoor heating and cooling demands, eliminating drafty starts and temperature swings while conserving energy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-efficiency DC blower motor\u003c\/strong\u003e: ECM blower delivers selectable external static pressure settings up to 0.80 in. w.g. (200 Pa) to accommodate standard or restrictive ductwork runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet operation\u003c\/strong\u003e: outdoor sound levels as low as 49 dB(A) and whisper-quiet indoor acoustic dampening provide peaceful home comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary electric heat readiness\u003c\/strong\u003e: air handler accommodates factory-engineered slide-in auxiliary electric heating elements for severe polar vortex contingency backup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCapacity varieties \u0026amp; sizing\u003c\/h2\u003e\n\u003cp\u003eChoosing the proper tonnage ensures balanced air distribution, comprehensive dehumidification in humid Ontario summers, and heating coverage during peak winter heating degree days:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2.5 Ton \/ 30,000 BTU\/h (Outdoor: PUZ-HA30NKA \/ Air Handler: PVA-A30AA7)\u003c\/strong\u003e: optimized for high-efficiency modern homes, semi-detached properties, and well-insulated residences up to 140–185 m² (1,500–2,000 sq ft). Delivers up to 34,000 BTU\/h maximum winter heating capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3.0 Ton \/ 36,000 BTU\/h (Outdoor: PUZ-HA36NKA \/ Air Handler: PVA-A36AA7)\u003c\/strong\u003e: ideal for typical detached Canadian family homes measuring 185–230 m² (2,000–2,500 sq ft). Delivers up to 40,000 BTU\/h maximum winter heating output with strong sub-zero thermal retention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3.5 Ton \/ 42,000 BTU\/h (Outdoor: PUZ-HA42NKA \/ Air Handler: PVA-A42AA7)\u003c\/strong\u003e: high-output central configuration for large custom homes measuring 230–300+ m² (2,500–3,500 sq ft) or properties with extensive exterior glazing requiring robust heating performance. Maximum heating output reaches 48,000 BTU\/h.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003e2.5 Ton (30,000 BTU)\u003c\/th\u003e\n\u003cth\u003e3.0 Ton (36,000 BTU)\u003c\/th\u003e\n\u003cth\u003e3.5 Ton (42,000 BTU)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eModel Identification\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003ePUZ-HA30NKA\u003c\/td\u003e\n\u003ctd\u003ePUZ-HA36NKA\u003c\/td\u003e\n\u003ctd\u003ePUZ-HA42NKA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor air handler\u003c\/td\u003e\n\u003ctd\u003ePVA-A30AA7\u003c\/td\u003e\n\u003ctd\u003ePVA-A36AA7\u003c\/td\u003e\n\u003ctd\u003ePVA-A42AA7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem configuration\u003c\/td\u003e\n\u003ctd\u003eCentrally ducted split\u003c\/td\u003e\n\u003ctd\u003eCentrally ducted split\u003c\/td\u003e\n\u003ctd\u003eCentrally ducted split\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eThermal Performance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling rated capacity\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h (8.8 kW)\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (10.5 kW)\u003c\/td\u003e\n\u003ctd\u003e42,000 BTU\/h (12.3 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating rated capacity (47 °F)\u003c\/td\u003e\n\u003ctd\u003e32,000 BTU\/h (9.4 kW)\u003c\/td\u003e\n\u003ctd\u003e40,000 BTU\/h (11.7 kW)\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h (14.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity at 5 °F (-15 °C)\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h (100% rated)\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (100% rated)\u003c\/td\u003e\n\u003ctd\u003e42,000 BTU\/h (100% rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum heating operating temp\u003c\/td\u003e\n\u003ctd\u003e-30 °C (-22 °F)\u003c\/td\u003e\n\u003ctd\u003e-30 °C (-22 °F)\u003c\/td\u003e\n\u003ctd\u003e-30 °C (-22 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ SEER rating\u003c\/td\u003e\n\u003ctd\u003eUp to 16.0 SEER\u003c\/td\u003e\n\u003ctd\u003eUp to 15.5 SEER\u003c\/td\u003e\n\u003ctd\u003eUp to 15.3 SEER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 \/ HSPF rating\u003c\/td\u003e\n\u003ctd\u003eUp to 10.5 HSPF\u003c\/td\u003e\n\u003ctd\u003eUp to 10.0 HSPF\u003c\/td\u003e\n\u003ctd\u003eUp to 9.5 HSPF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP at 47 °F\u003c\/td\u003e\n\u003ctd\u003e3.60\u003c\/td\u003e\n\u003ctd\u003e3.55\u003c\/td\u003e\n\u003ctd\u003e3.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP at 5 °F\u003c\/td\u003e\n\u003ctd\u003e2.05\u003c\/td\u003e\n\u003ctd\u003e1.98\u003c\/td\u003e\n\u003ctd\u003e1.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eAir Handler (Indoor)\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower type\u003c\/td\u003e\n\u003ctd\u003eHigh-efficiency ECM motor\u003c\/td\u003e\n\u003ctd\u003eHigh-efficiency ECM motor\u003c\/td\u003e\n\u003ctd\u003eHigh-efficiency ECM motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal static pressure (ESP)\u003c\/td\u003e\n\u003ctd\u003e0.30 to 0.80 in. w.g.\u003c\/td\u003e\n\u003ctd\u003e0.30 to 0.80 in. w.g.\u003c\/td\u003e\n\u003ctd\u003e0.30 to 0.80 in. w.g.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated airflow (dry)\u003c\/td\u003e\n\u003ctd\u003e875 CFM\u003c\/td\u003e\n\u003ctd\u003e1,050 CFM\u003c\/td\u003e\n\u003ctd\u003e1,262 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCabinet orientations\u003c\/td\u003e\n\u003ctd\u003eUpflow \/ Downflow \/ Horizontal\u003c\/td\u003e\n\u003ctd\u003eUpflow \/ Downflow \/ Horizontal\u003c\/td\u003e\n\u003ctd\u003eUpflow \/ Downflow \/ Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e432 × 548 × 1,372 mm (17\"×21.6\"×54\")\u003c\/td\u003e\n\u003ctd\u003e533 × 548 × 1,372 mm (21\"×21.6\"×54\")\u003c\/td\u003e\n\u003ctd\u003e635 × 548 × 1,372 mm (25\"×21.6\"×54\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (indoor)\u003c\/td\u003e\n\u003ctd\u003e51 kg (113 lb)\u003c\/td\u003e\n\u003ctd\u003e59 kg (130 lb)\u003c\/td\u003e\n\u003ctd\u003e78 kg (172 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eOutdoor Heat Pump\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor type\u003c\/td\u003e\n\u003ctd\u003eHyper-Heat Inverter scroll\u003c\/td\u003e\n\u003ctd\u003eHyper-Heat Inverter scroll\u003c\/td\u003e\n\u003ctd\u003eHyper-Heat Inverter scroll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-410A (pre-charged)\u003c\/td\u003e\n\u003ctd\u003eR-410A (pre-charged)\u003c\/td\u003e\n\u003ctd\u003eR-410A (pre-charged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound pressure level\u003c\/td\u003e\n\u003ctd\u003e49 dB(A)\u003c\/td\u003e\n\u003ctd\u003e51 dB(A)\u003c\/td\u003e\n\u003ctd\u003e51 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e1,050 × 330 × 1,338 mm\u003c\/td\u003e\n\u003ctd\u003e1,050 × 330 × 1,338 mm\u003c\/td\u003e\n\u003ctd\u003e1,050 × 330 × 1,338 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (outdoor)\u003c\/td\u003e\n\u003ctd\u003e120 kg (265 lb)\u003c\/td\u003e\n\u003ctd\u003e124 kg (273 lb)\u003c\/td\u003e\n\u003ctd\u003e130 kg (287 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eElectrical \u0026amp; Refrigerant Piping\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 VAC, 1-phase, 60 Hz\u003c\/td\u003e\n\u003ctd\u003e208\/230 VAC, 1-phase, 60 Hz\u003c\/td\u003e\n\u003ctd\u003e208\/230 VAC, 1-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended breaker size\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant line size (Liquid \/ Gas)\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. \/ 5\/8 in. flanged\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. \/ 5\/8 in. flanged\u003c\/td\u003e\n\u003ctd\u003e3\/8 in. \/ 5\/8 in. flanged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax piping length\u003c\/td\u003e\n\u003ctd\u003e75 m (245 ft)\u003c\/td\u003e\n\u003ctd\u003e75 m (245 ft)\u003c\/td\u003e\n\u003ctd\u003e75 m (245 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax elevation difference\u003c\/td\u003e\n\u003ctd\u003e30 m (100 ft)\u003c\/td\u003e\n\u003ctd\u003e30 m (100 ft)\u003c\/td\u003e\n\u003ctd\u003e30 m (100 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional heat loss calculation\u003c\/strong\u003e: ensure a certified HVAC technician performs a CSA F280 heat-gain\/heat-loss calculation on your home to select between 2.5-ton, 3.0-ton, or 3.5-ton systems accurately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuctwork static pressure evaluation\u003c\/strong\u003e: existing supply and return trunks should be inspected to ensure proper static pressure and CFM airflow capacity for heat pump operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor unit winter mounting\u003c\/strong\u003e: in Canadian snow regions, outdoor condensing units must be installed on a raised wall bracket or snow stand at least 300–450 mm (12–18 in.) above the historical snow line with clear drainage for defrost condensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical panel capacity\u003c\/strong\u003e: requires a dedicated 208\/230 V 40 A dual-pole breaker for the outdoor unit, plus independent electrical circuit service if optional auxiliary electric backup heat kits are installed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermostat compatibility\u003c\/strong\u003e: compatible with Mitsubishi Electric smart controllers (such as the kumo cloud interface, MHK2 wireless touch controller) or standard 24 VAC smart thermostats via an optional thermostat interface module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHave questions about cold-climate heat pump sizing, ductwork compatibility, or winter performance? Request a product quote and our equipment team will assist you.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eDoes the Zuba Central PVA air handler replace an existing oil, gas, or electric furnace?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. The multi-position PVA ducted air handler directly connects to standard residential ductwork, replacing traditional furnaces with a high-efficiency variable-capacity ECM blower system.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eCan backup auxiliary heat be added for extreme Ontario weather?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. Optional factory electric heat kits integrate seamlessly into the PVA air handler for supplementary or emergency heating.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat lineset pipe sizes are required?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe 3.0-ton system requires a 3\/8-inch liquid line and a 5\/8-inch suction vapor line insulated with 1\/2-inch wall closed-cell foam insulation.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat thermostat controls can be used with Zuba Central?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe system can be operated with Mitsubishi’s proprietary kumo cloud wireless interface, a PAR-40MAAU wall controller, or standard 24 V smart thermostats (like ecobee) using the optional PAC-PAC-US445CN-1 thermostat adapter interface.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat is the seasonal cooling efficiency rating?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe system achieves up to 18.0 SEER2 and up to 10.0 HSPF2, providing exceptional year-round climate efficiency in Canadian homes.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eDoes the outdoor unit include a factory base pan heater?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eYes. Canadian-spec PUZ-HA Hyper-Heat units come equipped with a factory-installed base pan heater to prevent melted condensate from freezing and creating ice dams during winter defrost cycles.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat mounting elevation is required for Canadian installations?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe outdoor condenser must be installed on heavy-duty wall brackets or an elevated stand at least 18 to 24 inches above local historical snow lines to allow clear drainage during defrost.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.mitsubishitechinfo.ca\/sites\/default\/files\/SB_PVA-A42AA4_PUZ-HA42NKA4_201705_0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSubmittal engineering data sheet — Mitsubishi Zuba Central PVA-A and PUZ-HA series heat pump system (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.mitsubishitechinfo.ca\/sites\/default\/files\/Zuba%2030%20Heating%20Performance_0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHeating performance data — Mitsubishi Zuba Central capacity and COP performance curve (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.mitsubishitechinfo.ca\/sites\/default\/files\/P-Series_Compatibility_Matrix.pdf\" target=\"_blank\" rel=\"noopener\"\u003eTechnical compatibility matrix — Mitsubishi Electric P-Series outdoor units and air handlers (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.mitsubishitechinfo.ca\/sites\/default\/files\/P_PAB_300_17_001_PVA-A-AA7-Release.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct engineering release bulletin — PVA-A multi-position air handling units (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications derived from Mitsubishi Electric Sales Canada (MESCA) Zuba Central submittal data SB_PVA-A42AA4_PUZ-HA42NKA4, Zuba 30 heating performance engineering data, and P-Series compatibility technical documentation. Specifications are subject to change by the manufacturer.\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; Safety Notice:\u003c\/strong\u003e Cold-climate central heat pump systems must be installed by a licensed HVAC technician and certified electrician following Mitsubishi Electric guidelines to ensure proper refrigerant charge, airflow balance, and warranty protection.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"2.5 Ton (30,000 BTU\/h)","offer_id":53964481691942,"sku":"PUZ-HA30NKA \/ PVA-A30AA7","price":9850.0,"currency_code":"CAD","in_stock":true},{"title":"3.0 Ton (36,000 BTU\/h)","offer_id":53964481724710,"sku":"PUZ-HA36NKA \/ PVA-A36AA7","price":10850.0,"currency_code":"CAD","in_stock":true},{"title":"3.5 Ton (42,000 BTU\/h)","offer_id":53964481757478,"sku":"PUZ-HA42NKA \/ PVA-A42AA7","price":11950.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/mitsubishi_zuba_1_system_9a6f366c-3eb7-4141-9601-96bea9d84df2.jpg?v=1792997289","url":"https:\/\/avlshop.ca\/products\/mitsubishi-zuba-central-heat-pump","provider":"AVL Shop","version":"1.0","type":"link"}