{"product_id":"pentair-clean-and-clear-plus-cartridge-filter","title":"Pentair Clean \u0026 Clear Plus Cartridge Filter","description":"\u003cp\u003e\u003cstrong\u003eCrystal clear water with commercial-grade cartridge efficiency and zero backwashing.\u003c\/strong\u003e The Pentair Clean \u0026amp; Clear Plus cartridge filter features a corrosion-resistant, injection-molded fiberglass-reinforced polypropylene tank with four easily accessible, coreless cartridge elements. By eliminating the need for backwashing, the Clean \u0026amp; Clear Plus prevents the loss of thousands of litres of heated, chemically treated water each swimming season.\u003c\/p\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuad-cartridge coreless design\u003c\/strong\u003e — four large-capacity polyester cartridges maximize filtration area, prolonging cleaning cycles to as little as once per season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInjection-molded fiberglass tank\u003c\/strong\u003e — chemical-resistant composite vessel engineered for supreme durability and high burst pressure under Canadian freeze-thaw cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamp ring with safety latch\u003c\/strong\u003e — heavy-duty tension ring securely seals tank halves with an audible safety latch for foolproof reassembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous internal air relief\u003c\/strong\u003e — High Flow™ manual air relief valve and internal continuous air bypass safely release trapped air during operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100% backwash-free operation\u003c\/strong\u003e — conserves water and pool chemicals while complying with municipal environmental bylaws.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eCCP320\u003c\/th\u003e\n\u003cth\u003eCCP420\u003c\/th\u003e\n\u003cth\u003eCCP520\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltration Area\u003c\/td\u003e\n\u003ctd\u003e320 sq. ft.\u003c\/td\u003e\n\u003ctd\u003e420 sq. ft.\u003c\/td\u003e\n\u003ctd\u003e520 sq. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign Flow Rate\u003c\/td\u003e\n\u003ctd\u003e120 GPM (454 LPM)\u003c\/td\u003e\n\u003ctd\u003e150 GPM (568 LPM)\u003c\/td\u003e\n\u003ctd\u003e150 GPM (568 LPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurnover Capacity (8 hr)\u003c\/td\u003e\n\u003ctd\u003e57,600 Gallons\u003c\/td\u003e\n\u003ctd\u003e72,000 Gallons\u003c\/td\u003e\n\u003ctd\u003e72,000 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurnover Capacity (10 hr)\u003c\/td\u003e\n\u003ctd\u003e72,000 Gallons\u003c\/td\u003e\n\u003ctd\u003e90,000 Gallons\u003c\/td\u003e\n\u003ctd\u003e90,000 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurnover Capacity (12 hr)\u003c\/td\u003e\n\u003ctd\u003e86,400 Gallons\u003c\/td\u003e\n\u003ctd\u003e108,000 Gallons\u003c\/td\u003e\n\u003ctd\u003e108,000 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlumbing Union Size\u003c\/td\u003e\n\u003ctd\u003e2 in. Slip\u003c\/td\u003e\n\u003ctd\u003e2 in. Slip\u003c\/td\u003e\n\u003ctd\u003e2 in. Slip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank Diameter\u003c\/td\u003e\n\u003ctd\u003e21.5 in.\u003c\/td\u003e\n\u003ctd\u003e21.5 in.\u003c\/td\u003e\n\u003ctd\u003e21.5 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank Height\u003c\/td\u003e\n\u003ctd\u003e43 in.\u003c\/td\u003e\n\u003ctd\u003e49 in.\u003c\/td\u003e\n\u003ctd\u003e56 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCartridge Count\u003c\/td\u003e\n\u003ctd\u003e4 Elements\u003c\/td\u003e\n\u003ctd\u003e4 Elements\u003c\/td\u003e\n\u003ctd\u003e4 Elements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eBefore you buy\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFootprint: Ensure equipment pad has at least 3 feet of vertical clearance above the tank for removing the top lid and cartridge cluster.\u003c\/li\u003e\n\u003cli\u003eEco compliance: Ideal for locations where municipal sewer bylaws prohibit chlorinated pool discharge into storm drains.\u003c\/li\u003e\n\u003cli\u003eWinterizing: Open air bleeder, drain tank thoroughly, rinse cartridges, and store in a dry indoor garage or basement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/filters\/clean-and-clear-family\/clean-and-clear-plus\/clean-and-clear-plus-guides-manuals\/clean-and-clear-plus-install-guide-2025-english.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; user's guide — Pentair Clean \u0026amp; Clear Plus (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/filters\/clean-and-clear-family\/clean-and-clear-plus\/clean-and-clear-plus-guides-manuals\/clean-and-clear-plus-cleaning-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSell sheet — Pentair Clean \u0026amp; Clear Plus (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhy choose a Clean \u0026amp; Clear Plus over a single-cartridge filter?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe Clean \u0026amp; Clear Plus splits the water flow across four large cartridge elements rather than forcing it through a single small core. This lowers the pressure drop, extends the interval between cleanings to once or twice a year, and dramatically extends cartridge life.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eWhat size Clean \u0026amp; Clear Plus is recommended for a residential pool?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eThe CCP420 (420 sq ft) is the undisputed sweet spot for most Canadian backyard pools up to 25,000 gallons. For very large in-ground pools or pools with heavy surrounding trees, the CCP520 (520 sq ft) delivers maximum dirt-holding capacity.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cdetails class=\"details\"\u003e\u003csummary\u003e\u003cstrong\u003eHow often do the four cartridges need to be replaced?\u003c\/strong\u003e\u003c\/summary\u003e\u003cdiv class=\"details-content\"\u003e\u003cp\u003eWith proper semi-annual hose cleaning and indoor winter storage, genuine Pentair cartridge elements typically last 3 to 5 swimming seasons before replacement pleats are needed.\u003c\/p\u003e\u003c\/div\u003e\u003c\/details\u003e\n\u003cp\u003e\u003csmall\u003eSpecifications from Pentair Water Pool and Spa technical documentation.\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; Safety Notice:\u003c\/strong\u003e High-pressure pool cartridge filters must be installed and maintained in strict accordance with the manufacturer's manual. Always relieve tank air pressure before servicing the clamp band.\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"320 Sq. Ft. (CCP320)","offer_id":54048037732646,"sku":"160340","price":1539.0,"currency_code":"CAD","in_stock":true},{"title":"420 Sq. Ft. (CCP420)","offer_id":54048047923494,"sku":"160301","price":1689.0,"currency_code":"CAD","in_stock":false},{"title":"520 Sq. Ft. (CCP520)","offer_id":54048047956262,"sku":"160332","price":1889.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/8521\/7830\/files\/pentair_clean_clear_plus.png?v=1792117219","url":"https:\/\/avlshop.ca\/products\/pentair-clean-and-clear-plus-cartridge-filter","provider":"AVL Shop","version":"1.0","type":"link"}