OFFICIAL SPECIFICATION
Parts 3 Years | Field Labor 1 Year
Capacity
Fuel
Catalog Preview

Online ordering coming soon. Contact us to confirm availability and shipping.

Freight cost is included in your written quote before you pay.

How a quote works

  1. Send the model and your city or postal code.
  2. Get a written equipment-only quote by email, with freight included.
  3. Approve the quote and pay by secure invoice, e-Transfer, bank transfer, PayPal or Shop Pay.

Pay by Interac e-Transfer on orders of $2,000 or more and save 1.5%.

Questions? Call 647-466-6989

Fulfillment Option Ontario Delivery Quotes
✔ Heavy items ship by freight, quoted to your address before you pay.
Buying equipment only
Operated by AVL Custom Homes Inc.
📦 What's included

The equipment as listed by the manufacturer. Check the specifications and documents below.

🔧 Installation

Not included. Installed by an independent licensed TSSA/ESA contractor you choose.

🚚 Freight on quote

Heavy items ship by freight. We quote the freight cost before you pay anything.

A compact, low-NOx gas pool and spa heater with a cupronickel heat exchanger in every size. The Hayward Universal H-Series heats in-ground pools and spas on natural gas or propane, with inputs from 150,000 to 399,900 BTU/h. A forced-draft burner, hot surface ignition and a built-in header bypass make it a practical choice for new pools and for replacing an older heater.

View Full Specifications & Downloads

Technical specifications

Heating TypeGas Heater
Warranty2026 EXPERT LINE® RESIDENTIAL WARRANTY TERMS
All Products* Exceptions listed below
In Ground
Standard
Parts 3 Years
Field Labor 1 Year
Heaters
No additional warranty.
Source: Hayward warrantyWarranty is provided by the manufacturer under its own terms. See the source link for full details.
Highlights & Innovation

Key features

  • Cupronickel heat exchanger as standard — Hayward fits cupronickel tubes on every Universal H-Series model for resistance to salt water and pool chemicals.
  • Built-in low-loss bypass — Hayward's patented header bypass keeps the right flow through the heat exchanger, up to a maximum system flow of 473 L/min (125 US gpm).
  • Forced-draft combustion — a combustion blower moves air through the burner at a set rate, so no high-wind stack is needed outdoors.
  • Low NOx emissions — meets the South Coast Air Quality Management District Rule 1146.2 low-NOx standard.
  • 120 or 240 V power — factory wired for 240 V AC and field-convertible to 120 V AC with the supplied jumper; 5.5 A maximum.
  • Front-panel service access — routine service is done from the front, and junction boxes on both sides simplify electrical and automation wiring.
Selection Matrix

Choosing a size

Hayward sizes the heater by pool surface area. Its recommendation assumes a 17 °C (30 °F) temperature rise, an average wind of 5.6 km/h (3.5 mph) and an elevation up to 610 m (2,000 ft). For an indoor pool, Hayward divides the surface area by three.

Model H150FD H200FD H250FD H400FD
Pool surface area up to 41.8 m² (450 ft²) 55.7 m² (600 ft²) 69.7 m² (750 ft²) 111.5 m² (1,200 ft²)
Time to heat a covered 1,514 L (400 US gal) spa by 17 °C (30 °F) 48 min 36 min 29 min 18 min
Technical Data & Ratings

Specifications

Model comparison

Model H150FD H200FD H250FD H400FD
Natural gas model H150FDN H200FDN H250FDN H400FDN
Propane model H150FDP H200FDP H250FDP H400FDP
Gas input 150,000 BTU/h (44.0 kW) 199,900 BTU/h (58.6 kW) 250,000 BTU/h (73.3 kW) 399,900 BTU/h (117.2 kW)
Thermal efficiency 82.7% 83% 84% 84%
Minimum water flow 76 L/min (20 US gpm) 76 L/min (20 US gpm) 95 L/min (25 US gpm) 114 L/min (30 US gpm)
Width 48.3 cm (19 in) 55.9 cm (22 in) 63.5 cm (25 in) 86.4 cm (34 in)
Weight 61.2 kg (135 lb) 63.5 kg (140 lb) 74.8 kg (165 lb) 88.5 kg (195 lb)

General

Brand Hayward
Series Universal H-Series Low NOx (FD models)
Product type Gas heater for in-ground pools and spas
Fuel Natural gas (…FDN) or propane (…FDP), set at the factory
Heat exchanger Cupronickel tubes
Ignition Silicon nitride hot surface ignition
Combustion Forced draft

Water connections and flow

Plumbing connections 2 in × 2½ in CPVC unions
Maximum water flow 473 L/min (125 US gpm), all models; install a manual bypass valve above this flow
Bypass Integral low-loss header bypass

Gas supply

Gas connection at heater ¾ in
Inlet pressure, natural gas 4.5–10.5 in w.c. (1.12–2.62 kPa)
Inlet pressure, propane 10.0–13.0 in w.c. (2.49–3.24 kPa)
Manifold pressure Natural gas 1.8–2.2 in w.c.; propane 6.8–7.0 in w.c.
Altitude as shipped Up to 610 m (2,000 ft); high-altitude kit FDXLHAK1931 above that

Electrical

Power supply 120 or 240 V AC, 60 Hz, single phase (factory wired for 240 V)
Maximum current 5.5 A
Recommended circuit protection 15 A

Dimensions and clearances

Height × depth 61.0 × 74.9 cm (24 × 29½ in), all models; width per model above
Clearance, front 46 cm (18 in)
Clearance, back 15 cm (6 in); 30 cm (12 in) in front of vinyl siding
Clearance, sides 30 cm (12 in) on the water-connection side, 15 cm (6 in) on the opposite side
Clearance, top Unobstructed outdoors; 91 cm (36 in) indoors

Certification

Design certification ETL (USA and Canada); design compliant with ANSI Z21.56 and CSA 4.7
Installation codes in Canada CAN/CSA B149.1 (gas) and CSA C22.1 Canadian Electrical Code, Part 1
Emissions SCAQMD Rule 1146.2 (low NOx)
Canadian Installation & Compliance

Before you buy

  • Choose the size from your pool's surface area (see the table above); a pool cover reduces heat loss and heating time.
  • Check that your gas meter or propane tank can supply the heater's full input on top of your other gas appliances. Propane tanks must be outdoors and sized for vaporization at the lowest expected temperature.
  • Your pump must deliver at least the model's minimum flow, with a dirty filter and any in-floor cleaner running. Above 473 L/min (125 US gpm) a manual bypass valve is required.
  • Plan a dedicated 120 V or 240 V circuit with 15 A protection, and a gas shut-off valve outside the cabinet within 1.8 m (6 ft) of the heater.
  • Indoor installations need Hayward's indoor vent kit for the heater size; installations above 610 m (2,000 ft) need the high-altitude kit.
  • Fuel is set at the factory. Changing between natural gas and propane needs a Hayward conversion kit installed by a qualified service agency, where local codes allow it.
  • Hayward specifies installation by a qualified technician in line with CAN/CSA B149.1, the Canadian Electrical Code and local codes.

Not sure which size suits your pool? Request a quote and we will confirm the right configuration, pricing and availability.

Technical Details

Frequently asked questions

What heat exchanger material is used in the Hayward Universal H-Series?

The Universal H-Series features a cupronickel finned-tube heat exchanger that provides superior corrosion resistance against pool chemistry fluctuations, high flow velocities, and saltwater chlorination systems compared to standard copper.

What is the thermal efficiency rating of the H-Series gas heater?

The Hayward Universal H-Series achieves an 83% to 84% thermal efficiency rating, utilizing forced-draft combustion and insulated ceramic combustion chambers to maximize heat transfer to pool water.

What electrical connection does the heater require?

The internal electronic ignition and digital control circuitry feature a universal dual-voltage transformer configured for 120 V or 240 V single-phase 60 Hz electrical supply.

What water flow rate is needed for the H250FD?

The H250FD (250,000 BTU/h) requires a minimum water flow rate of 30 GPM (114 L/min) and supports maximum flow up to 125 GPM (473 L/min) using its internal automatic bypass valve.

What gas supply pressure is required for natural gas operation?

Natural gas models require an incoming manifold supply pressure between 5.0 inches and 10.5 inches water column (W.C.). A dedicated licensed gas technician must measure supply pressure under full firing load per CSA B149.1.

Can this heater be converted from natural gas to propane?

Yes. Hayward provides official certified conversion kits containing factory orifices and gas valve spring regulator parts. Conversions must be completed and tagged by a licensed gas technician.

What plumbing pipe size connects to the water header?

The heater includes 2-inch by 2.5-inch CPVC union plumbing nuts that connect directly to standard 2-inch Schedule 40 PVC swimming pool plumbing.

Does the heater produce low emissions?

Yes. The forced-draft low-NOx combustion system complies with clean air standards, reducing nitrogen oxide emissions below 40 ng/J.

Can the heater be installed indoors?

Yes. When installed indoors, an official Hayward indoor direct-vent adapter kit and ULC-S636 approved Category III/IV venting must be installed following local building codes and CSA B149.1.

How is the Hayward H-Series winterized for Canadian winter?

Turn off the gas supply shutoff valve and power disconnect. Remove both drain plugs located on the front and rear plastic water headers. Disconnect CPVC union collars, and blow low-pressure compressed air through the exchanger to remove all trapped water.

Verified Engineering Assets

Documents

Specifications from Hayward's In-Ground Pool/Spa Gas Heaters owner's manual (51300004201 Rev E), Hayward Canada product pages for each model, and the Universal H-Series bilingual brochure (LITUHS22C, 2022) for sizing and spa heat-up times. kW and metric values converted from Hayward's imperial figures. Specifications are subject to change by the manufacturer. View the Hayward Universal H-Series owner's manual (PDF).

Common questions

Is installation included?

No. AVL Shop sells equipment only. Installation is done by an independent licensed contractor that you hire.

How is freight charged?

Freight cost is included in your written quote before you pay.

What warranty does this product have?

The manufacturer warranty applies. Where we have the manufacturer’s exact wording, it is shown in the Warranty row of the specifications on this page, with a link to the source.

How do I get a quote?

Use Request a quote on this page and send the model and your city or postal code.

You may also like